42
Spyder3 S3-14 and S3-24 Monochrome Camera User's Manual
03-032-20117-01
Teledyne DALSA
Mode 7: Internally Programmable Line Rate, Maximum Exposure
Time
In this m od e, the line rate is set internally w ith a m axim u m exp osu re tim e.
Figure 24: Mode 7 Camera Timing
Mode 8: Maximum Line Rate, Programmable Exposure Time
In this m od e, the exp osu re tim e is set internally w ith a m axim u m line rate.
Figure 25: Mode 8 Timing
Setting the Line Rate
Sets the camera’s line rate in Hz. Camera m ust be operating in either exposure m od e 2 or 7.
Camera Link Command
Parameter
Description
Notes
ssf f
Desired line rate in H z. Allow able
valu es are:
1k 1 tap :
300
-
36000
H z
1k 2 tap :
300
-
68000
H z
2k 1 tap :
300
-
18500
H z
2k 2 tap :
300
-
36000
H z
4k 2 tap :
300-18500
H z
To read the cu rrent line frequ ency, u se the
com m and
gcp
or
get
ssf
.
If you enter an invalid line rate frequ ency, an
error m essage is retu rned .
Example
ssf 10000
Programmable Period
Frame Period
Readout
CR Exposure Time
CR=Charge Reset
Frame Period
Programmable Period
CR Exposure Time
Readout
Exposure Time
Readout
Internal Sync
set
with Command
ssf
Line Period
Exposure Time
Readout
Line Period
EXSYNC Falling
Edge ignored
during readout
EXSYNC Falling
Edge ignored
during readout