Spyder3 S3-14 and S3-24 Monochrome Camera User's Manual
25
Teledyne DALSA
03-032-20117-01
Table 10: Spyder3 Input and Output
Symbol
Definition
Min (ns)
tw SYN C
The m inim u m low w id th of the EXSYN C p u lse w hen not in SMART
EXSYN C m od e.
100
tw SYN C
(SMART)
*
The m inim u m low w id th of the EXSYN C p u lse w hen in SMART EXSYN C
m od es to gu arantee the p hotosites are reset.
3,000
tw SYN C_IN T
The m inim u m w id th of the high p u lse w hen the ―SMART EXSYN C‖
featu re is tu rned off
100
tw SYN C_IN T
(SMART)
*
Is the integration time when the ―SMART EXSYNC‖ feature is available
and tu rned on. N ote that the m inim u m tim e is necessary to gu arantee
p rop er op eration.
3,000
tLIN E PERIOD
(t
LP
)
The m inim u m and m axim u m line tim es m ad e u p of tTransfer, tREADOUT
p lu s tOVERH EAD to m eet sp ecifications.
14,700 (1k 2 tap )
27,778 (1k 1 tap )
27,778 (2k 2 tap )
54,054 (2k 1 tap )
55,775 (4k 2 tap )
tTransfer
The tim e from the recep tion of the falling ed ge of EXSYN C to the rising
ed ge of LVAL w hen p retrigger is set to zero. Pretrigger red u ces the
number of clocks to the rising ed ge of LVAL but d oesn’t change the time to
the first valid p ixel. If the fixed integration tim e m od e of operation is
available and selected then the integration tim e is ad d ed to the sp ecified
valu e.
3,725 ±25 (1k
and 2k)
4,100±25 (4k)
tw Fixed Int.
Fixed Integration Tim e m od e of op eration for variable exsync frequ ency.
800
tREADOUT
Is the nu m ber of p ixels p er tap tim es the read ou t clock p eriod .
25,600 (1k 1 tap ))
12,800 (1k 2 tap )
51,200 (2k 1 tap )
25,600 (2k 2 tap )
51,200 (4k 2 tap )
tOVERH EAD
Is the nu m ber of p ixels that m u st elap se after the falling ed ge of LVAL
before the EXSYN C signal can be asserted . This tim e is u sed to clam p the
internal analog electronics
425±25
(All m od els)
thPR
Ap p lies w hen the PRIN exp osu re control featu re is enabled . The PRIN
signal m u st be held a m inim u m tim e after the EXSYN C falling ed ge to
avoid losing the integrated charge
To Be
Determ ined
tw PR_LOW
Minim u m Low tim e to assu re com p lete p hotosite reset
3,000
tPR_SET
The nom inal tim e that the p hoto sites are integrating. Clock
synchronization w ill lead to integration tim e jitter, w hich is show n in the
sp ecification as +/ - valu es. The u ser shou ld com m and tim es greater than
these to ensu re prop er charge transfer from the photosites. Failu re to m eet
this requ irem ent m ay resu lt in bloom ing in the H orizontal Shift Register.
3,000