DS21354/DS21554 3.3V/5V E1 Single-Chip Transceivers
37 of 124
CCR2: COMMON CONTROL REGISTER 2 (Address = 1A Hex)
(MSB)
(LSB)
ECUS VCRFS AAIS ARA RSERC
LOTCMC RFF RFE
SYMBOL
POSITION
NAME AND DESCRIPTION
ECUS CCR2.7
Error Counter Update Select.
See Section
for details.
0 = update error counters once a second
1 = update error counters every 62.5ms (500 frames)
VCRFS CCR2.6
VCR Function Select.
See Section
for details.
0 = count BiPolar Violations (BPVs)
1 = count Code Violations (CVs)
AAIS CCR2.5
Automatic Transmit AIS Generation.
0 = disabled
1 = enabled
ARA CCR2.4
Automatic Remote Alarm Generation.
0 = disabled
1 = enabled
RSERC CCR2.3
RSER Control.
0 = allow RSER to output data as received under all conditions
1 = force RSER to one under loss of frame alignment conditions
LOTCMC CCR2.2
Loss of Transmit Clock Mux Control.
Determines whether the
transmit-side formatter should switch to the ever-present RCLKO if the
TCLK should fail to transition (see
0 = do not switch to RCLKO if TCLK stops
1 = switch to RCLKO if TCLK stops
RFF CCR2.1
Receive Force Freeze.
Freezes receive-side signaling at RSIG (and TS16
in RSER if CCR3.3 = 1); will override Receive Freeze Enable (RFE).
See Section
for details.
0 = do not force a freeze event
1 = force a freeze event
RFE CCR2.0
Receive Freeze Enable.
See Section
for details.
0 = no freezing of receive signaling data will occur
1 = allow freezing of receive signaling data at RSIG (and TS16 in RSER