8 SYSTEM TROUBLESHOOTING
This chapter describes the meaning of each Alarm indication and provides recommendations regarding how to troubleshoot the Dali dual-band DAS comprised of
tHost™
unit, and network of
t43™
remote units.
Ref
tHost™
Alarms
Description
Troubleshooting steps
per band
tHost™
UL LO Out of Lock
Uplink path not operational due to
failure of reference frequency
generation in the
tHost™
.
•
Ensure unit is operating within valid temperature range.
•
Attempt selection of another sub-band.
•
Attempt relocking the LO through a
tHost™
reboot.
tHost™
DL LO Out of Lock
Downlink path not operational due to
failure of reference frequency
generation in the
tHost™
.
•
Ensure unit is operating within valid temperature range.
•
Attempt selection of another sub-band.
•
Attempt relocking the LO through a
tHost™ reboot
tHost™
DL RF Shutdown Enabled
User has manually disabled the
downlink path in the
tHost™
.
•
Re-enable the DL path from the
tHost™
main page.
tHost™
UL RF Shutdown Enabled
User has manually disabled the
uplink path in the
tHost™
.
•
Re-enable the DL path from the
tHost™
main page.
tHost™
DL Low Power
Input power from the base station is
below configured threshold.
•
Check level of input signal from base station with power meter.
•
Adjust alarm threshold on
tHost™
main page.
tHost™
DL High Power
Input power from the base station is
above configured threshold.
•
Check level of input signal from base station with power meter.
•
Adjust alarm threshold on
tHost™
main page.
Unit level
tHost™
Power Supply Failure
•
Replace
tHost
TM
unit
tHost™
Optical Link Failure
•
Replace
tHost
TM
unit or repair optical fiber transport or replace
t43
TM
unit
t43™
Alarms
per band
t43™
UL LO Out of Lock
Uplink path not operational due to
failure of reference frequency
generation in the
tHost™
.
•
Ensure unit is operating within valid temperature range.
•
Attempt selection of another sub-band.
•
Attempt relocking the LO through a
t43™
restart.
t43™
DL LO Out of Lock
Downlink path not operational due to
failure of reference frequency
generation in the
tHost™
.
•
Ensure unit is operating within valid temperature range.
•
Attempt selection of another sub-band.
•
Attempt relocking the LO through a
t43™
restart.