8
MAN#650508B
GAUGE SETUP AND CALIBRATION
The function switch is used to enter setup mode for all of the gauges. All of the setup is done from the
speedometer message display. To get into setup; press and hold the function switch while turning the key on. Press and
release the switch to advance through the menus below; when on the desired option press and hold the switch to select
setup for that particular gauge/function.
SPEEDOMETER SETUP
Main Menu
Sub Menu
Description
COLOR
ALL
Set all colors and brightness the same
BACKLIGHT
Set backlight color and brightness
NEEDLE
Set needle color and brightness
DISPLAY
Set message display color and brightness
SPEED
ADJUST
Adjust speed while driving
AUTO CAL
Drive a measured mile (or km) to calibrate speed
UNIT
Select MPH or km/h unit
SERVICE
Set miles to service reset value or turn off
ppm info
Display current speed calibration pulses per mile
ODO PRESET
One time odometer preset
(only available for the first 100 miles)
TACH
WARN
Set high RPM warning point
cylinder
Set engine cylinder count for tachometer calibation
signal
Set tachometer signal type (this should be set to normal)
OIL TEMP
UNIT
Select F or C temperature unit
WARNING
Set high warning point
TEST
Display sender resistance for troubleshooting
OIL PSI
SENDER
Select stock or Dakota Digital sender
WARNING
Set low warning point
TEST
Display sender resistance for troubleshooting
FUEL
SENDER
Select fuel sender
RANGE
Enable/Disable/Reset distance to empty
TEST
Display sender resistance for troubleshooting
VOLTAGE
LO WARNING
Set low volts warning point
DISPLAY
CONTRAST
Message center contrast adjustment for SPEED/TACH
PRFM DISP
Display performance readings on SPEED or TACH
DIGITAL
Display digital readings for connected gauges on SPEED or TACH
WARN
Display warning pop-ups on SPEED or TACH
MBM DISP
Display MBM gauges on SPEED or TACH
GAUGES
Show which gauges are connected to the speedometer
MBMS
Show MB
M’s connected to the speedometer and set warning points
GEAR
LEARN
Learn gears based on speed and RPM
PRESET
Set gears based on factory setup
DONE
Exit