11
MAN#650508B
oil temp
Engine oil temperature setup menu
Press and release the switch until “
oil temp
” is displayed, then press and hold the switch until the display blanks.
Release the switch. The display will
show “
unit
”, “
warning
”, “
test
”, or “
DONE
”.
Press and release the switch to change the selection, press and hold the switch to select it.
unit
Temperature F/C selection
Press and release the switch until “
unit
” is displayed, then press and hold the switch until the display blanks.
Release the switch. The display will show
UNIT
and
F
for Fahrenheit or
C
for Celsius.
Press and release the switch until the desired setting is displayed.
Press and hold the switch to save the setting.
warning
High oil temperature warning setup
Press and release the sw
itch until “
warning
” is displayed, then press and hold the switch until the display blanks.
Release the switch. The display will
show “
hi
”, the current warning (225F – 375F), and “
warning
”.
Press and release the switch to change the value, press and hold the switch to select it.
test
Resistance test
Press and release the switch until “
test
” is displayed, then press and hold the switch until the display blanks.
Press and release the switch to change the gauge. Press and hold the switch to exit.
oil psi
Engine oil temperature setup menu
Press and release the switch until “
oil psi
” is displayed, then press and hold the switch until the display blanks.
Release the switch. The display will
show “
sender
”, “
warning
”, “
test
”, or “
DONE
”.
Press and release the switch to change the selection, press and hold the switch to select it.
sender
Pressure sender selection
Press and release the switch until “
sender
” is displayed, then press and hold the switch until the display blanks.
Release the switch. The display will show
“
HD 60
” or “
DD 75
”.
Press and release the switch until the desired setting is displayed.
Press and hold the switch to save the setting.
warning
Low oil pressure warning setup
Press and release the switch until “
warning
” is displayed, then press and hold the switch until the display blanks.
Release the switch. The display will
show “
LO
”, the current warning (0 – 30), and “
warning
”.
Press and release the switch to change the value, press and hold the switch to select it.
test
Resistance test
Press an
d release the switch until “
test
” is displayed, then press and hold the switch until the display blanks.
The resistance measured from 0
– 999 will be shown. Press and release the switch to exit.
fuel
Fuel level setup menu
Press and release the switch unt
il “
fuel
” is displayed, then press and hold the switch until the display blanks.
Release the switch. The display will
show “
sender
”, “
range
”, “
test
”, or “
DONE
”.
Press and release the switch to change the selection, press and hold the switch to select it.
Sender
Fuel sender selection
Press and release the switch until “
sender
” is displayed, then press and hold the switch until the display blanks.
Release the switch. The display will show
“
dD 08
” (2008-2013), “
dD 04
” (2004-2007), “
HD 08
” or “
HD 04
”. The HD settings
should only be used if a stock fuel gauge is being left connected and operating on the bike.
Press and release the switch until the desired setting is displayed.
Press and hold the switch to save the setting.
range
Distance to empty setup
The range
reading will initially show the word “
range
” until a tank of gas has been driven to allow the gauge to
complete its setup based on your driving. Begin with a full tank of gas and do not refill it until it gets below ¼ tank of gas.
This can be done on multiple trips as long as no fuel is added before it gets low enough. After the initial setup the display will
show “
E
” followed by the calculated distance to empty. This will count down, making adjustments as necessary, until the
range is 35 miles (56
km) or less and then it will show “
r low
”. The gauge will continue to make adjustments to match your
driving habits with each fill up. After the initial setup you are not required to wait for the fuel to get below ¼ tank before
refilling.
Press and relea
se the switch until “
range
” is displayed, then press and hold the switch until the display blanks.
Release the switch. The display will
show “
OFF
” or “
On
” indicating whether the feature is active.
Press and release the switch to change the value, press and hold the switch to select it.
If
ON
is selected, the next option is
“
done
” or “
reset
” “
learning
”. To reset or start a new distance learning cycle, select
“
reset learning
” and hold the switch.
test
Resistance test
Press and release the switch until “
test
” is displayed, then press and hold the switch until the display blanks.
The resistance measured from 0