Dakota Digital BIM-01-2-HLLY Скачать руководство пользователя страница 8

 

[8] 

 

MAN #650588D 

HDX and RTX setup:

  

 

**HDX/RTX systems can be configured with the Dakota Digital app for Apple and Android devices** 

 

HDX and RTX Operations 

 

HDX:

 With the ignition key already on, press and hold both switches to enter SETUP, release when instructed. 

o

 

If using the external rocker switch, hold SW2 (II) while turning the ignition on. 

o

 

Release the switch when SETUP is shown. 

o

 

Left switch on display is SW1, and right switch on display is SW2 

 

RTX:

 With the ignition off, press hold SW2 (II) while turning the ignition key on to enter SETUP 

o

 

Release the switch when SETUP is shown. 

 

BOTH:

 When holding for an option, release the button when the screens says 

“RELEASE”

 

 

BOTH:

 

You may skip to whichever reading you’d like to configure below; they do not need to be done in order.  

 

BOTH:

 After making a selection, tap a switch and select BACK to save and return to the main menu, then select 

EXIT SETUP to return to normal operation. 

 

BOTH:

 SWI (left) moves up 

 the menu list, SWII (right) moves down 

 the menu list 

 
Obtaining speed from the BIM-01-2-HLLY  
     Dominator, HP, and Terminator X Max - Not Sniper, nor Terminator X 

 

Tap SWII (right) switch until SPEED is selected. Press and hold SWII (right) switch to enter SPEED menu. 

 

Tap SWII (right) switch until INPUT is displayed. Press and hold SWII (right) switch to enter INPUT menu. 

 

SIGNAL will be is displayed. Press and hold SWII (right) switch to enter SIGNAL menu. 

 

Tap right switch until BIM is displayed. Press and hold SWII (right) switch to select BIM. 

 

When SIGNAL is displayed again, tap switch until BACK is displayed, then hold to return to INPUT. 

 

When INPUT is displayed again, tap switch until BACK is displayed, then hold the switch to exit.  

o

 

NOTE

: The AUTO CAL, auto calibration, is not accessible. 

o

 

ADJUST now only alters the percentage of speed by +/- 25%. 

 

After the engine is running, enter setup and go to ADJUST.  

 

While driving a known speed, SWI and SWII (left/right) can adjust speed. 

 

Percentage can also be adjusted without driving. 

 

Tap SWII (right) to increment up to 125%. 

 

Tap SW1 (left) to decrement down to 75%. 

 

The speed will be displayed in the LCD along with the percent chosen. 

 

Once the speed is correct, hold either switches until RELEASE is displayed. 

 

You may now continue to exit the setup menu. 

o

 

The Dakota Digital Automotive app can also be used either while driving or not driving. 

 
Obtaining RPM from the BIM-01-2-HLLY 

 

Tap SWII (right) switch until TACH is selected. Press and hold SWII (right) switch to enter TACH menu. 

 

Tap SWII (right) switch until INPUT is displayed. Press and hold SWII (right) switch to enter INPUT menu. 

 

Tap SWII (right) switch until CYLINDER is displayed. Press and hold SWII (right) switch to select CYLINDER. 

 

Tap SWI (

left

) switch until BIM is displayed. Press and hold SWII (right) switch to select BIM. 

 

When INPUT is displayed again, tap until BACK is displayed, then hold the switch to exit. 
 

Obtaining engine temperature from the BIM-01-2-HLLY 

 

Tap SWII (right) switch until WATER is selected. Press and hold SWII (right) switch to enter WATER menu. 

 

Tap SWII (right) switch until INPUT is displayed. Press and hold SWII (right) switch to enter INPUT menu. 

 

Tap SWII (right) switch until BIM is displayed. Press and hold SWII (right) switch to select BIM. 

 

When INPUT is displayed again, tap until BACK is displayed, then hold the switch to exit. 
 

Obtaining oil pressure from the BIM-01-2-HLLY (not Sniper, if available in HP/Dominator) 

 

Tap SWII (right) switch until OIL is selected. Press and hold SWII (right) switch to enter OIL menu. 

 

Tap SWII (right) switch until INPUT is displayed. Press and hold SWII (right) switch to enter INPUT menu. 

 

Tap SWII (right) switch until BIM is displayed. Press and hold SWII (right) switch to select BIM. 

 

When INPUT is displayed again, tap until BACK is displayed, then hold the switch to exit. 

Содержание BIM-01-2-HLLY

Страница 1: ...h your particular kit There are two interface I O ports on the BIM 01 2 HLLYmodule Either one can be connected to the instrument system or to another module allowing several units to be daisy chained...

Страница 2: ...or 2 to Racepack and connect BIM cable to that CAN 1 or 2 cable Terminator HP and Dominator EFI speed input Data that should be available RPM Engine temp Intake manifold temp MAP boost A F ratio Data...

Страница 3: ...ay Sniper Hold button until a dash is displayed and then release Tap button to display then hold to save Note Speed Input is not a selectable menu option with selection Sniper does not send speed Term...

Страница 4: ...3 3X systems with a plastic case support adding BIMs Entering the VFD3 setup is done by holding SW1 I and turning the ignition to on or acc Once in setup one can move between speed tach volt water etc...

Страница 5: ...e displayed Press and hold SW1 for at least 3 seconds until changes to The displays should show and SENDER Press and hold SW1 for at least 3 seconds until changes to The speed display will show the cu...

Страница 6: ...When the desired percentage is reached hold SW1 I until DONE is displayed Tap SW1 I until SPEED DONE is displayed Press and hold SW1 I until a big DONE is displayed Obtaining RPM from the BIM 01 2 HL...

Страница 7: ...e SW1 I LCD1 should show SETUP SPEED Tap SW1 until SETUP OIL is displayed Press and hold SW1 I for at least 3 seconds until OIL SENDER is displayed Press and hold SW1 I for at least 3 seconds until SE...

Страница 8: ...speed by 25 After the engine is running enter setup and go to ADJUST While driving a known speed SWI and SWII left right can adjust speed Percentage can also be adjusted without driving Tap SWII right...

Страница 9: ...the switch to change the system o Standard Dominator or Terminator HP o Sniper o Terminator X only To save setting press and hold the switch until you see on the display then release the switch The di...

Страница 10: ...setup or tap to choose another menu option To set or change the ID number The ID will not normally need to be changed The fuel PSI and A F ratio readings both use bus ID s so if you have other BIM uni...

Страница 11: ...ged Module is damaged Connect to a location that has 12V key on power Inspect harness and repair or replace Return for service See Instructions below BIM display is scanning EFI adapter harness is not...

Страница 12: ...s product that should it under normal use and condition be proven defective in material or workmanship for the lifetime of the original vehicle it was installed in such defect s will be repaired or re...

Отзывы: