Dakota Digital BIM-01-2-HLLY Скачать руководство пользователя страница 3

 

[3] 

 

MAN #650588D 

Terminator, HP and Dominator EFI speed input setup, continued: 

 

If speed sensor is connected to Input #1 on J1A, pin A12 

 

Using the Holley computer software, the Input #1 must be labeled as 

Speed.

 

 

Ensure the 

Speed

 input is mapped to a frequency (

F

) Input Type on the Holley Pin Map. 

 

These settings will enable the Holley to send speed out on the Racepack CAN 

 

To monitor Input #1 on J1A, pin A12 you must enable the 



 setting within the BIM: 

 

Hold button on BIM-01-2-HLLY and turn ignition on, then release the button. 

 

Tap button to display



 (Input). 

 

Hold button until a dash (

) is displayed, and then release. 

 

Tap the button to display 



 

 

Hold button until a dash (

) is displayed, and then release. 

 

Tap button to display 



, then hold to save. 

 
Sniper EFI system setup: 

 
Data that should be available:  RPM, Engine temp, Intake/manifold temp, MAP/boost, A/F ratio. 

 

Holley system setup:

 No configuration within the Sniper EFI system or software is required. 

BIM-01-2-HLLY setup:

 The BIM must be configured to understand it will be talking to the Sniper EFI 

 

 

Hold button on BIM-01-2-HLLY and turn ignition on, then release the button. 

 

Tap button to display 



 (System). 

 

Hold button until a dash (

) is displayed, and then release. 

 

Tap the button to display 



(Sniper) 

 

Hold button until a dash (

) is displayed, and then release. 

 

Tap button to display 



, then hold to save. 

Note:

 Speed Input is not a selectable menu option with 



 selection 

– Sniper does not send speed. 

 

Terminator X, X Max EFI system setup: 

 
Data that should be available:  RPM, Engine temp, Intake/manifold temp, Boost only, A/F ratio, Oil pressure,  
Fuel pressure. 
Terminator X Max: Reads everything as the Terminator X, plus Vehicle speed.

 

 

Holley system setup: 

No configuration within the Sniper EFI system or software is required.

 

BIM-01-2-HLLY setup:

 The BIM must be configured to understand it will be talking to the Terminator X, X Max. 

 

 

Hold button on BIM-01-2-HLLY and turn ignition on, then release the button. 

 

Tap button to display 



 (System). 

 

Hold button until a dash (

) is displayed, and then release. 

 

Tap the button to display 



(Terminator X) 

 

Hold button until a dash (

) is displayed, and then release. 

 

Tap button to display 



, then hold to save. 

 

EFI MAP/boost: 

This module is programmed to monitor MAP(PSI/inHg) and boost (PSI/inHg) data broadcasted on the Holley EFI. MAP 
and boost will both be displayed with the boost label on our system. MAP is the default reading preset from the factory. If 
you wish to monitor boost pressure you must enable the 



 (boost) option through the setup menu. Please see setup 

steps on page 10. 
 

Note:

 Terminator X will not show MAP, only boost PSI readings. Speed input is not a selectable menu option with 



 

selection. 
 

 

 

Содержание BIM-01-2-HLLY

Страница 1: ...h your particular kit There are two interface I O ports on the BIM 01 2 HLLYmodule Either one can be connected to the instrument system or to another module allowing several units to be daisy chained...

Страница 2: ...or 2 to Racepack and connect BIM cable to that CAN 1 or 2 cable Terminator HP and Dominator EFI speed input Data that should be available RPM Engine temp Intake manifold temp MAP boost A F ratio Data...

Страница 3: ...ay Sniper Hold button until a dash is displayed and then release Tap button to display then hold to save Note Speed Input is not a selectable menu option with selection Sniper does not send speed Term...

Страница 4: ...3 3X systems with a plastic case support adding BIMs Entering the VFD3 setup is done by holding SW1 I and turning the ignition to on or acc Once in setup one can move between speed tach volt water etc...

Страница 5: ...e displayed Press and hold SW1 for at least 3 seconds until changes to The displays should show and SENDER Press and hold SW1 for at least 3 seconds until changes to The speed display will show the cu...

Страница 6: ...When the desired percentage is reached hold SW1 I until DONE is displayed Tap SW1 I until SPEED DONE is displayed Press and hold SW1 I until a big DONE is displayed Obtaining RPM from the BIM 01 2 HL...

Страница 7: ...e SW1 I LCD1 should show SETUP SPEED Tap SW1 until SETUP OIL is displayed Press and hold SW1 I for at least 3 seconds until OIL SENDER is displayed Press and hold SW1 I for at least 3 seconds until SE...

Страница 8: ...speed by 25 After the engine is running enter setup and go to ADJUST While driving a known speed SWI and SWII left right can adjust speed Percentage can also be adjusted without driving Tap SWII right...

Страница 9: ...the switch to change the system o Standard Dominator or Terminator HP o Sniper o Terminator X only To save setting press and hold the switch until you see on the display then release the switch The di...

Страница 10: ...setup or tap to choose another menu option To set or change the ID number The ID will not normally need to be changed The fuel PSI and A F ratio readings both use bus ID s so if you have other BIM uni...

Страница 11: ...ged Module is damaged Connect to a location that has 12V key on power Inspect harness and repair or replace Return for service See Instructions below BIM display is scanning EFI adapter harness is not...

Страница 12: ...s product that should it under normal use and condition be proven defective in material or workmanship for the lifetime of the original vehicle it was installed in such defect s will be repaired or re...