Dakota Digital BIM-01-2-HLLY Скачать руководство пользователя страница 11

 

[11] 

 

MAN #650588D 

Quick tips: 

While the BIM is operating, the dot in the upper left corner of the display will indicate the status.  On steady indicates it is 
powered up but not receiving any BIM bus activity.  Flashing indicates it is communicating on the BIM bus. 
If the display shows “



” then it is scanning to try and communicate with the EFI system bus but cannot get an answer. 

To see the sensor and channel status on the BIM display, press and hold the switch. The display will cycle through 
several screens.  The first will show the bus type (“



” Holley EFI). The next screens will indicate which (if any) extended 

data is available: “



” for intake/manifold temp, “



” for engine oil pressure. 

 
Troubleshooting guide: 
 

Problem 

Possible cause 

Solution 

BIM will not light up at all 

  PWR wire does not have power. 

  Connect to a different ground location 

  Power/data harness is damaged. 

  Module is damaged. 

  Connect to a location that has +12V key-on  

power. 

  Inspect harness and repair or replace. 

  Return for service. (See Instructions below) 

BIM display is scanning “



” 

  EFI adapter harness is not connected 

 

  The EFI system is not compatible 

  The EFI is not powered on. 

 

The EFI CAN is not configured to “Racepak” 
 

  Connect the appropriate harness to the EFI  

CAN. 

  Verify compatibility. 

  Verify EFI system is powered on. 

  Verify CAN settings within EFI software.  

  If connected to Dominator, HP or Terminator verify  



 is set to 



 in the BIMs setup menu 

BIM has a steady dot lit 

  Interface cable is not connected 

 

  Interface cable is loose. 

  On VHX systems, the BIM display for this is  

disabled. 

  Connect the supplied data cable between the  

BIM unit and the instrument system control box. 

  Make sure both ends of the cable are seated. 

  Follow instructions in VHX manual to enable  

the BIM display screen. 

BIM display shows 



:

” 

  Data cable is damaged. 

  Another module on the bus is damaged or  

connected improperly. 

  Inspect and replace the data cable. 

  Inspect other modules on the bus. 

 

Содержание BIM-01-2-HLLY

Страница 1: ...h your particular kit There are two interface I O ports on the BIM 01 2 HLLYmodule Either one can be connected to the instrument system or to another module allowing several units to be daisy chained...

Страница 2: ...or 2 to Racepack and connect BIM cable to that CAN 1 or 2 cable Terminator HP and Dominator EFI speed input Data that should be available RPM Engine temp Intake manifold temp MAP boost A F ratio Data...

Страница 3: ...ay Sniper Hold button until a dash is displayed and then release Tap button to display then hold to save Note Speed Input is not a selectable menu option with selection Sniper does not send speed Term...

Страница 4: ...3 3X systems with a plastic case support adding BIMs Entering the VFD3 setup is done by holding SW1 I and turning the ignition to on or acc Once in setup one can move between speed tach volt water etc...

Страница 5: ...e displayed Press and hold SW1 for at least 3 seconds until changes to The displays should show and SENDER Press and hold SW1 for at least 3 seconds until changes to The speed display will show the cu...

Страница 6: ...When the desired percentage is reached hold SW1 I until DONE is displayed Tap SW1 I until SPEED DONE is displayed Press and hold SW1 I until a big DONE is displayed Obtaining RPM from the BIM 01 2 HL...

Страница 7: ...e SW1 I LCD1 should show SETUP SPEED Tap SW1 until SETUP OIL is displayed Press and hold SW1 I for at least 3 seconds until OIL SENDER is displayed Press and hold SW1 I for at least 3 seconds until SE...

Страница 8: ...speed by 25 After the engine is running enter setup and go to ADJUST While driving a known speed SWI and SWII left right can adjust speed Percentage can also be adjusted without driving Tap SWII right...

Страница 9: ...the switch to change the system o Standard Dominator or Terminator HP o Sniper o Terminator X only To save setting press and hold the switch until you see on the display then release the switch The di...

Страница 10: ...setup or tap to choose another menu option To set or change the ID number The ID will not normally need to be changed The fuel PSI and A F ratio readings both use bus ID s so if you have other BIM uni...

Страница 11: ...ged Module is damaged Connect to a location that has 12V key on power Inspect harness and repair or replace Return for service See Instructions below BIM display is scanning EFI adapter harness is not...

Страница 12: ...s product that should it under normal use and condition be proven defective in material or workmanship for the lifetime of the original vehicle it was installed in such defect s will be repaired or re...

Отзывы: