SiUS331604E
Wiring Diagrams
Appendix
246
FXUQ18/24/30/36PVJU
INDOOR UNIT
R2T
R
3T
T2
PNK
S1L
PO
WER SUPPL
Y
INDOOR UNIT
WHT
T1
GRN
t˚
t˚
X2M
A1P
YL
W
F2
V1R
NE
F1U
C105
+
L1
RED
X15A
X18A
X17A
F1
ORG
+
Z1F
X30A
L2
WHT
-
BLU
P2
P2
X27A
BLK
P1
P1
GRN/YL
W
HAP
MSW
X35A
M4S
PS
X36A
MSW
M3S
X7A
X20A
X25A
MSW
M2S
N=1
Z1C
X81A
MSW
X16A
M1S
X81A
ORG
BLU
MS
M
M1P
BRN
X81A
X35A
RED
WHT
Y1E
t˚
R1T
WHT
R1T
MS
A3P
A
4P
M1F
A3P
A4P
A1P
X2M
X1M
Installation position
2
NO
TES
CONTR
OL BO
X
Installation position
1
CONTROL BOX
Installation position of SENSOR KIT
1
~
208/230V
60Hz
SENSOR KIT (Option)
Installation position
1
SENSOR KIT (Option)
Installation position
2
(NO
TE 6)
X1M
INPUT FR
OM
OUTSIDE (NO
TE 5)
TRANSMISSION
WIRING (NO
TE 2)
CENTRAL REMO
TE
CONTR
OLLER
WIRED REMO
TE
CONTR
OLLER
(OPTIONAL A
CCESSOR
Y)
(NO
TE 3)
1.
:
TERMINAL BLOCK , :
CONNECT
OR :
FIELD
WIRING
2.
IN CASE USING CENTRAL REMO
TE CONTR
OLLER, CONNECT IT
TO
THE
UNIT IN A
CCORD
ANCE
WITH
THE A
T
TA
CHED INST
ALLA
TION MANU
AL.
3.
IN CASE OF MAIN/SUB CHANGEO
VER,
SEE
THE INST
ALLA
TION MANU
AL A
T
TA
CHED
TO
REMO
TE CONTR
OLLER.
4.
SYMBOLS SHO
W AS FOLLO
WS:
BLK:
BLA
CK RED:
RED BLU:
BLUE
WHT
: WHITE
YL
W:
YELLO
W GRN:
GREEN ORG:
ORANGE BRN:
BR
O
WN PNK:
PINK.
5.
WHEN CONNECTING
THE INPUT
WIRING FR
OM OUTSIDE, FORCED OFF OR ON/OFF CONTR
OL OPERA
TION
CAN BE SELECTED BY
THE REMO
TE CONTR
OLLER.
SEE INST
ALLA
TION MANU
AL FOR MORE DET
AILS
.
6.
CLASS 2
WIRE
A1P
C105
F1U
HAP
M1F
M1P
M1S•M2S
M3S•M4S
R1T
R2T•R3T
S1L
V1R
X1M
X2M
Y1E
Z1F
Z1C
PS
A3P
A4P
X35A
X81A
PRINTED CIRCUIT BO
ARD
CAP
A
C
IT
OR (M1F)
FUSE
FLASHING LAMP
(SER
VICE MONIT
OR
GREEN)
MO
T
OR (INDOOR F
AN)
MO
T
OR (DRAIN PUMP)
MO
T
OR (SWING BLADE)
THERMIST
OR (AIR)
THERMIST
OR (COIL)
FLO
A
T SWITCH
DIODE BRIDGE
TERMINAL BLOCK
TERMINAL BLOCK
ELECTR
ONIC EXP
ANSION
VA
LV
E
NOISE FIL
TER
FERRITE CORE
PO
WER SUPPL
Y CIRCUIT
SENSOR KIT
PRINTED CIRCUIT BO
ARD
PRINTED CIRCUIT BO
ARD
CONNECT
OR FOR OPTIONAL P
A
R
T
S
CONNECT
OR
(PO
WER SUPPL
Y FOR AD
APT
OR)
CONNECT
OR
(SENSOR KIT)
3D090218
Содержание VRV IV-S RXTQ-TAVJU Series
Страница 1: ...Service Manual SiUS331604E RXTQ36 48 60TAVJU Heat Pump 60 Hz...
Страница 253: ...SiUS331604E Wiring Diagrams Appendix 240 1 Wiring Diagrams 1 1 Outdoor Unit RXTQ36TAVJU 3D100495A...
Страница 254: ...Wiring Diagrams SiUS331604E 241 Appendix RXTQ48TAVJU 3D100496A...
Страница 255: ...SiUS331604E Wiring Diagrams Appendix 242 RXTQ60TAVJU 3D100497A...
Страница 260: ...Wiring Diagrams SiUS331604E 247 Appendix FXEQ07 09 12 15 18 24PVJU C 3D098557...
Страница 267: ...SiUS331604E Wiring Diagrams Appendix 254 FXTQ12 18 24 30 36 42 48 54PAVJU 3D065036G...
Страница 269: ...SiUS331604E Wiring Diagrams Appendix 256 1 3 2 Energy Recovery Ventilator VAM Series VAM300 470 600GVJU 3D073269C...
Страница 270: ...Wiring Diagrams SiUS331604E 257 Appendix VAM1200GVJU 3D073270C...
Страница 271: ...Revision History Month Year Version Revised contents 06 2016 SiUS331604E First edition...