SiBE041213E
Outdoor Unit
Printed Circuit Board Connector Wiring Diagram
12
2.3
RXS50K2V1B
Main PCB
Caution
Replace the PCB if you accidentally cut the jumpers other than J6 and J8.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
1) S10
Connector for [S11] on filter PCB
2) S12
Connector for [HL4] [HN4] on filter PCB
3) S20
Connector for electronic expansion valve coil
4) S40
Connector for overload protector
5) S50
Connector for magnetic relay
6) S70
Connector for fan motor
7) S80
Connector for four way valve coil
8) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
9) HL3, HN3
Connector for [HL2] [HN2] on filter PCB
10)U, V, W
Terminal for compressor
11)FU2
Fuse (3.15 A, 250 V)
12)LED A
LED for service monitor (green)
13)V1
Varistor
14)J6
Jumper for facility setting
∗
Refer to page 108 for detail.
15)J8
Jumper for improvement of defrost performance
∗
Refer to page 110 for detail.
S80
S10
2P273854-7
S70
S20
S40
S90
FU2
S50
LED A
J8
J6
U, V, W
HN3
HL3
S12
V1
Содержание RXS35K2V1B
Страница 12: ...SiBE041213E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Страница 14: ...SiBE041213E 3 Specifications Part 2 Specifications 1 Specifications 4 ...
Страница 59: ...SiBE041213E Remote Controller 48 Part 5 Remote Controller 1 Remote Controller 49 ...
Страница 111: ...SiBE041213E Check Service Diagnosis 100 42 class 50 class R12266 Tester 1 2 3 4 Tester 1 2 3 4 R14700 ...
Страница 113: ...SiBE041213E Check Service Diagnosis 102 42 class 50 class R18241 Power module Power module R16692 ...
Страница 129: ...Revision History Month Year Version Revised contents 05 2013 SiBE041213E First edition ...