Outdoor Unit
SiBE041213E
11
Printed Circuit Board Connector Wiring Diagram
2.2
RXS42K2V1B
Main PCB
Caution
Replace the PCB if you accidentally cut the jumpers other than J4 and J5.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
1) S20
Connector for electronic expansion valve coil
2) S40
Connector for overload protector
3) S70
Connector for fan motor
4) S80
Connector for four way valve coil
5) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
6) U, V, W
Connector for compressor
7) HL1, HN1, S
Connector for terminal board
8) E (E2)
Connector for earth wire
9) HR1, HR2
Connector for reactor
10) LED A
LED for service monitor (green)
11) FU1, FU2
Fuse (3.15 A, 250 V)
12) FU3
Fuse (30 A, 250 V)
13) J4
Jumper for facility setting
∗
Refer to page 108 for detail.
14) J5
Jumper for improvement of defrost performance
∗
Refer to page 110 for detail.
15) V1, V3, V4
Varistor
HN1 HL1
E (E2)
S
V1
FU1
LED A
S80
S20
S90
S70
HR2
HR1
FU2
S40
J5
J4
U, V, W
2P208173-2
V3
V4
FU3
Содержание RXS35K2V1B
Страница 12: ...SiBE041213E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Страница 14: ...SiBE041213E 3 Specifications Part 2 Specifications 1 Specifications 4 ...
Страница 59: ...SiBE041213E Remote Controller 48 Part 5 Remote Controller 1 Remote Controller 49 ...
Страница 111: ...SiBE041213E Check Service Diagnosis 100 42 class 50 class R12266 Tester 1 2 3 4 Tester 1 2 3 4 R14700 ...
Страница 113: ...SiBE041213E Check Service Diagnosis 102 42 class 50 class R18241 Power module Power module R16692 ...
Страница 129: ...Revision History Month Year Version Revised contents 05 2013 SiBE041213E First edition ...