Piping Diagrams
SiBE041401E
113
Appendix
RXG50L2V1B
OUTDOOR UNIT
HEAT EXCHANGER
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
7.9 CuT
12.7 CuT
CAPILLARY TUBE 1
4.0 CuT
7.9 CuT
7.9 CuT
4.0 CuT
7.9 CuT
7.9 CuT
REFRIGERANT FLOW
6.4 CuT
CAPILLARY TUBE 2
7.9 CuT
CAPILLARY TUBE 3
4.0 CuT
COOLING
HEATING
6.4 CuT
4.0 CuT
CAPILLARY TUBE 4
6.4 CuT
M
PROPELLER FAN
EV
FILTER
12.7 CuT
6.4 CuT
9.5 CuT
12.7 CuT
RECEIVER
7.9 CuT
12.7 CuT
MUFFLER
MUFFLER
6.4 CuT
7.9 CuT
9.5 CuT
MUFFLER
7.9 CuT
12.7 CuT
COMPRESSOR
HEAT
EXCHANGER
THERMISTOR
DISCHARGE PIPE
THERMISTOR
FOUR WAY
VALVE
ON : HEATING
OUTDOOR TEMPERATURE
THERMISTOR
MUFFLER
WITH
FILTER
ELECTRONIC
EXPANSION
VALVE
LIQUID
STOP VALVE
GAS STOP VALVE
WITH SERVICE PORT
FIELD PIPING
(6.4 CuT)
FIELD PIPING
(12.7 CuT)
3D080605C