SiBE041401E
Field Settings
Trial Operation and Field Settings
108
3.3
Standby Electricity Saving
Outline
This function turns power supply OFF to the outdoor unit and sets the indoor unit into standby
electricity saving mode, thus reducing the power consumption of the air conditioner.
Detail
Following procedure is required for turning ON the function.
1. Check that the main power supply is turned OFF. Turn OFF if it has not been turned OFF.
2. Remove the stop valve cover.
3. Disconnect the selective connector for standby electricity saving.
4. Turn ON the main power supply.
20/25/35 class
50 class
Caution
Before connecting or disconnecting the selective connector for standby electricity saving, make
sure that the main power supply is turned OFF.
1
2
3
1
2
3
(R18981)
Function ON
Function OFF
(factory set)
(R18926)
Function ON
Function OFF
(factory set)
Содержание RXG20L2V1B
Страница 12: ...SiBE041401E 1 List of Functions Part 1 List of Functions 1 Functions 2 ...
Страница 14: ...SiBE041401E 3 Specifications Part 2 Specifications 1 Specifications 4 ...
Страница 60: ...SiBE041401E 49 Remote Controller Part 5 Remote Controller 1 Remote controller 50 ...
Страница 113: ...SiBE041401E Check Service Diagnosis 102 50 class Diode bridge R19944 ...