SiUS092230EA
BRC1E73
Part 5 Remote Controller
105
1. Operation mode selector button
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
2. Fan speed control button
3. Menu/OK button
4. Up button
5. Down button
6. Right button
7. Left button
8. On/Off button
9. Operation lamp
10. Cancel button
11. LCD (with backlight)
Press this button to select the operation
mode of your preference.
* Available modes vary with the indoor unit
model.
Used to highlight the next items on the
left-hand side.
Each screen is scrolled in the left-hand
direction.
Press this button and system will start.
Press this button again to stop the system.
This lamp illuminates solid green during
normal operation.
This lamp flashes if an error occurs.
Used to return to the previous screen.
The backlight will be illuminated for
approximately 30 seconds by pressing any
button.
If two remote controllers are used to control
a single indoor unit, only the controller
accessed first will have backlight
functionality.
Press this button to select the fan speed of
your preference.
* Available fan speeds vary with the indoor
unit model.
Used to enter the main menu.
Used to enter the selected item.
Used to raise the setpoint.
The item above the current selection will be
highlighted.
(The highlighted items will be scrolled
continuously when the button is
continuously pressed.)
Used to change the selected item.
Used to lower the setpoint.
The item below the current selection will be
highlighted.
(The highlighted items will be scrolled
continuously when the button is
continuously pressed.)
Used to change the selected item.
Used to highlight the next items on the
right-hand side.
Each screen is scrolled in the right-hand
direction.
Содержание RX-W Series
Страница 1: ... Applied Models Inverter Pair Heat Pump Service Manual SiUS092230EA Inverter Pair RX W Series ...
Страница 15: ...SiUS092230EA Part 1 General Information 9 1 Applicable Models 10 2 Functions 11 Part 1 General Information ...
Страница 107: ...SiUS092230EA BRC082A41W BRC082A42W S Part 5 Remote Controller 101 4 BRC082A41W BRC082A42W S R23936 R23937 ...
Страница 151: ...SiUS092230EA Troubleshooting for FDMQ FFQ Series Part 6 Service Diagnosis 145 Reference Check No 02 Refer to P 191 ...
Страница 207: ...SiUS092230EA Check Part 6 Service Diagnosis 201 15 18 24 class R25105 1 2 3 4 Multimeter ...
Страница 209: ...SiUS092230EA Check Part 6 Service Diagnosis 203 15 18 24 class R20704 W V U DC_P1 DC_N1 ...
Страница 238: ...Piping Diagrams SiUS092230EA 232 Part 8 Appendix 1 2 Outdoor Unit RX09 12WMVJU9 RX15 18WMVJU9 3D135014 3D141501 ...
Страница 239: ...SiUS092230EA Piping Diagrams Part 8 Appendix 233 RX24WMVJU9 3D141502 ...
Страница 246: ...Operation Limit SiUS092230EA 240 Part 8 Appendix 3 Operation Limit RX09 12 15 18 24WMVJU9 3D092209F ...