3-24
I/O ON
I/O
Power OFF
Unit OFF
All lights on
(for 3 sec.)
Preparation
(for 18 sec.)
Circuit Breaker ON
Circuit Breaker OFF
after setting change
( OFF when no setting changed)
for 3 sec.
for 3 sec.
for 3 sec.
for 3 sec.
CASE 2
CASE 1
CASE 3 (Refer to 3.8.2)
※
10
Optional
Function
Setting
※
11
Basic
Function
Setting
※
12
Optional
Condition
Setting
※
13
Container
I.D & Time
Setting
PTI
for 3 sec.
for 3 sec.
USDA: OFF (or 3 or 4)
S
dHU: OFF (or ON)
DECOS
3
: C (or B or A)
S
Log. Interval: 30 (or 15 or 60 or 120)
S
REC SEN: ON (or OFF)
S
OC-SET: Sing (or Dual)
S
HP: 10 (or 5)
S
DISP: OFF (or ON)
S
COMP: 100 (or 33)
S
REHEAT: OFF (or ON)
Container I.D
S
Controller
Time
CHARTLS: OFF (or ON)
S
USDA 1/2: 2 (or 1)
S
H001~H006
S
d-1
**
~d-2
**
S
C/F : C (or F)
3.3.3 Setting flow chart
This configuration setting flow shall be utilized, when
CASE 1) USDA transportation setting is required (
※
10 Optional Function Setting)
CASE 2) Container ID shall to be subjected to change from another container for emergency use.
(
※
13 Container ID & Time Setting)
CASE 3) Controller is replaced to new one. (All setting in
※
10-13 shall be set.)
NOTE 1 : All initial settings are pre-setted, when the unit is delivered.
2 : In case to complete the setting change, CIRCUIT BREAKER shall be turned off