Indoor Unit
SiBE611027_A
61
Removal Procedure
1.5
Removal of PCB from Main Electrical Box
Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the shield plate.
1
Pull out the clamp.
2
Unfasten the 8 hooks
and remove the shield
plate.
2. Remove the PCBs.
1
Unfasten the 2 hooks
of the sensor PCB.
2
Disconnect the
connector [S49] and
remove the sensor
PCB.
[S49]: control PCB
Refer to page 7 for detail.
(R12459)
Hook
Hook
Hook
Shield plate
(R12759)
(R12456)
Sensor
PCB
(R12457)
[S49]