SiBE611027_A
Service Check Function
Service Diagnosis
42
Check Method 2
1. Press the 3 buttons (TEMP
▲
, TEMP
▼
, MODE) at the same time.
The figure of the ten’s place blinks.
2. Press the TEMP
▲
or
▼
button and change the figure until you hear the sound of “beep” or
“pi pi”.
3. Diagnose by the sound.
★
“pi” : The figure of the ten’s place does not accord with the error code.
★
“pi pi” : The figure of the ten’s place accords with the error code but the one’s not.
★
“beep” : The both figures of the ten’s and one’s place accord with the error code.
(The figures indicated when you hear the "beep" sound are error code.
→
Refer to
page 44.)
4. Press the MODE button.
The figure of the one’s place blinks.
(R12741)
(R8382)
(R12742)
(R12743)
(R8385)