SiBE04-101
Troubleshooting
Service Diagnosis
87
4. Troubleshooting
4.1
Indoor Units
- : Not used for troubleshooting
∗
: Varies depending on the cases.
Indication on the
remote controller
Description of the Fault
Details of fault
(Refer to the
indicated
page.)
00
OR
∗
Indoor unit in normal condition (Conduct a diagnosis of the outdoor unit.)
—
A1
Inverter unit - Faulty indoor unit PCB
89
A5
Operation halt due to the freeze protection function or high pressure
control
90
A6
Faulty fan motor (DC motor stop)
DC motor
91
A6
Faulty fan motor (AC motor stop)
AC motor
93
C4
Heat exchanger temperature thermistor or related abnormality
94
C9
Suction air thermistor or related abnormality
94
CA
Discharge air thermistor or related abnormality
94
∗
Faulty indoor unit PCB
95
96
∗
OR
U4
Faulty power supply or indoor unit PCB
97
U4
Signal transmission error (between indoor and outdoor units)
98
UA
Faulty indoor / outdoor power supply specification
99
∗
OR
E8
Operation halt due to detection of input overcurrent
106
E5
Stoppage by OL actuation/Melt-down by temperature fuse
102
E6
Opeartion halt due to compressor seizing
104
E7
DC fan motor seizing
105
F3
Abnormal discharge pipe temperature
101
H6
Operation halt due to faulty position detection sensor
108
H8
Operation halt due to detection of CT abnormality
109
H9
Operation halt due to outside air thermistor abnormality
112
J3
Operation halt due to discharge pipe thermistor abnormality, or due to
detection of disconnected discharge pipe thermistor
112
J6
Operation halt due to outdoor unit heat exchanger thermistor abnormality
112
L5
Operation halt due to detection of output overcurrent
110
U0
Operation halt due to detection of insufficient gas
113
U2
Main circuit overvoltage or low voltage
115
SiBE04-101.book Page 87 Monday, October 15, 2001 3:08 PM