General Functions
SiBE04-101
26
Main Function
1.6.2
Floor / Ceiling Suspended Dual Type
Details of the
Action
Caution
The direction of airflow in horizontal swing can be set in auto mode or in any position by remote controller.
Set the direction of airflow by swing motion stopping operation at a position at which user want to stop the
motion while watching the flap.
In the case of floor/ceiling type, since the indication on the liquid crystal display and the actual direction
of the flap do not agree depending on the installation pattern, the indication on the remote controller
goes out if auto swing is not effected.
Swing Angle Range
Swing angle is common for ceiling type and floor type.
The following description is for the swing angle for ceiling type.
The vertical louvre is of manual type. It turns 60 degrees to the right and 60 degrees to the left. It has a
movable range of 120 degrees in total.
Indication on the remote controller in auto swing
Indication on the remote controller at the time
when auto swing is not effected
Vertical swing motions
are repeated automatically.
Indication goes out.
(No display)
(R1028)
95˚
65˚
Heating mode
0 degree based on
the horizontal line.
(R1029)
20˚
40˚
Cooling / Dry / Fan mode
0 degree based on
the horizontal line.
∗
Fan mode is available for the models of cooling-only.
SiBE04-101.book Page 26 Monday, October 15, 2001 3:08 PM