9 Troubleshooting
Operation manual
26
EZESHP20 EZLSHP20AUAW1B
Exigo E1500 Trailer Refrigeration Unit
4P726855-1 – 2023.03
Display
code
Color
Description
F023
Red
Cond Fan1 Modbus Anomaly: No
communication
F024
Red
Evap Fan1 Modbus Anomaly: No
communication
F025
Red
Inverter Modbus Anomaly: No communication
F026
Red
HMI Modbus Anomaly: No communication with
HMI
F027
Red
Defrost end timer anomaly: Defrost exceed max
time
F034
Red
Low pressure Alarm stop
F035
Red
Evap Fan2 Modbus Anomaly: No
communication
F036
Red
Cond Fan2 Modbus Anomaly: No
communication
F037
Red
Condenser Fan 1 Under Voltage Alarm
F038
Red
Condenser Fan 2 Under Voltage Alarm
F039
Red
Condenser Fan 1 Over Voltage Alarm
F040
Red
Condenser Fan 2 Over Voltage Alarm
F041
Red
Condenser Fan 1 Over Temperature Alarm
F042
Red
Condenser Fan 2 Over Temperature Alarm
F043
Red
Condenser Fan 1 Overcurrent Alarm
F044
Red
Condenser Fan 2 Overcurrent Alarm
F045
Red
Evaporator Fan 1 Under Voltage Alarm
F046
Red
Evaporator Fan 2 Under Voltage Alarm
F047
Red
Evaporator Fan 1 Over Voltage Alarm
F048
Red
Evaporator Fan 2 Over Voltage Alarm
F049
Red
Evaporator Fan 1 Over Temperature Alarm
F050
Red
Evaporator Fan 2 Over Temperature Alarm
F051
Red
Evaporator Fan 1 Overcurrent Alarm
F052
Red
Evaporator Fan 2 Overcurrent Alarm
F053
Red
Heatsink overheated (Hardware related)
F054
Red
Over current at acceleration state (Hardware
related)
F055
Red
Over current at deceleration state (Hardware
related)
F056
Red
DC BUS under voltage
F057
Red
DC Bus over voltage
F058
Red
Overcurrent at acceleration state
F059
Red
Over current at steady state
F060
Red
Over current at deceleration state
F061
Red
Communication loss time out
F062
Red
Heatsink temperature sensor error
F063
Red
Discharge temperature sensor error
F064
Red
Discharge temperature overheated
F065
Red
Motor startup fail
F066
Red
Motor position loss
F067
Red
Emergency stop
F068
Red
Heatsink overheated (Software related)
F069
Red
Discharge temperature overheated (Software
related)
F070
Red
Overcurrent at steady state (Hardware related)
F071
Red
Compression ratio alarm
F072
Red
Heaters alarm
F073
Red
HPS activation
F074
Red
High Power consumption
F075
Red
Engine OFF or in stall
Display
code
Color
Description
F076
Red
Electrical problems
F078
Red
Max machine restart from protection
F079
Red
Abnormal PCB reset
F081
Red
High generator temperature
F082
Red
SH Anomaly
HF003
Red
Mobus communication with PCB Loss
HF004
Yellow Forced Grid unable to turn on
HF005
Red
Canbus communication loss with Converter
V1R
HF006
Orange Canbus communication to ECU Loss
HF007
Yellow Canbus communication to Battery Charger Loss
HF008
Orange Engine Starting Alarm
HF009
Red
Safety Stop Low Battery Voltage
HF010
Yellow Engine forced OFF
HF011
Red
Freeze State detected
HF012
Orange Engine High Temperature Prevent
HF013
Orange Insulation Loss
K01
Yellow Oil pressure error
K02
Yellow Engine overheat
K03
Yellow Coolant temperature sensor HIGH
K04
Yellow Coolant temperature sensor LOW
K05
Orange Battery voltage HIGH
K06
Orange Engine overrun
K07
Orange Power supply voltage LOW
K08
Orange Engine solenoid actuator is abnormal
K09
Yellow CANBUS error
K10
Orange Engine speed sensor abnormal
K11
Orange Speed sensor pulse abnormal
Z01
Red
Logic failure 1
Z02
Red
Watchdog
Z03
Red
Mismatch volt
Z04
Yellow Eeprom KO
Z05
Red
Logic failure 3
Z06
Red
Power failure 1
Z07
Red
Shorted output
Z08
Red
Can bus KO
Z09
Red
Overcurrent
Z10
Yellow High temp
Z11
Yellow Logic failure 2
Z12
Red
Wrong input volt
Z13
Red
Wrong marker EEP
Z14
Red
No mains
Z15
Red
Low temp
Z16
Red
Clk battery off
Z17
Red
Nodes mismatch
Z18
Red
Firmware mismatch
Z19
Red
BMS overvoltage
Z20
Red
Wrong protocol
Z21
Yellow Address claim failed
9.2
Symptoms that are NOT system
malfunctions
The following symptoms are NOT system malfunctions: