OPERATION MANUAL

EWAQ005AAV3P
EWAQ006AAV3P
EWAQ007AAV3P

EWYQ005AAV3P
EWYQ006AAV3P
EWYQ007AAV3P

Packaged air-cooled water chillers and

packaged reversible air to water heat pumps

Summary of Contents for EWAQ005AAV3P

Page 1: ...OPERATION MANUAL EWAQ005AAV3P EWAQ006AAV3P EWAQ007AAV3P EWYQ005AAV3P EWYQ006AAV3P EWYQ007AAV3P Packaged air cooled water chillers and packaged reversible air to water heat pumps ...

Page 2: ...full control over your installation It can control a cooling heating and a cooling only installation Both installations are available in multiple versions which vary in capacity Basic controller functions The basic controller functions are Turning the unit ON OFF Operation mode change over heating refer to Heating operation h on page 4 cooling refer to Cooling operation c on page 4 silent mode ref...

Page 3: ... icon is displayed whenever a function is not available in your configuration n may also appear due to the restrictions of the user permission level set by the installer 13 DEFROST MODE ICON d This icon indicates that the defrost mode is active 14 COMPRESSOR ICON ç This icon indicates that the compressor in the outdoor unit of the installation is active 15 PUMP ICON é This icon indicates that the c...

Page 4: ...ser can set the clock and day of the week The controller is equipped with a schedule timer that enables the user to schedule operations Setting the clock and day of the week is required to be able to use the schedule timer Setting the clock 1 Hold down the pr button for 5 seconds The clock read out and the day of week indicator start flashing 2 Use the pi and pj buttons to adjust the clock Each tim...

Page 5: ...ush the ba button for 5 seconds The b icon and the outgoing water temperature are displayed The icons l and are flashing 2 Use the pi and pj buttons to display The outdoor temperature u icon is flashing The outgoing water temperature h or c is flashing If no button is pressed for 5 seconds the controller leaves the display mode Automatic operation only for heating In automatic operation the controlle...

Page 6: ...will be executed You can always alter add or remove the programmed actions later When programming heating actions time and setpoint cooling actions are added automatically at the same time but with the predefined default cooling setpoint Conversely when programming cooling actions time and setpoint heating actions are added automatically at the same time but with the default heating setpoint The se...

Page 7: ...pressing the pr button 9 Use the button to select the action number you would like to program or to modify 10 Use the ba button to select x to switch both cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode You can change the shift value by means of the bi and bj buttons 11 Use the pi a...

Page 8: ...cooling or heating actions Consulting cooling or heating is carried out as follows 1 Press the button The actual mode is blinking 2 Use the pi and pj buttons to select the mode current mode or silent mode you want to consult The selected mode is blinking You can leave consultation by pressing the pr button To consult silent mode refer to Consulting silent mode actions on page 7 3 Press the button ...

Page 9: ...tton several times to return to normal operation MAINTENANCE Maintenance activities In order to ensure optimal availability of the unit a number of checks and inspections on the unit and the field wiring have to be carried out at regular intervals preferably yearly This maintenance should be carried out by your local Daikin technician Besides keeping the remote controller clean by means of a soft d...

Page 10: ...NOTES NOTES ...

Page 11: ......

Page 12: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PW27338 1 ...