7
Installation
Installer reference guide
28
ERLQ004~008CA + 08S18CA3VF
Daikin Altherma low temperature split
4P3662261 – 2014.01
7.2.3
To install the outdoor unit
CAUTION
Do NOT remove the protective cardboard before the unit is
installed properly.
1
Lift the outdoor unit as described in
"3.1.2 To remove the
accessories from the outdoor unit" on page 6
.
2
Install the outdoor unit as follows:
2x
2
a
a
1
a
Air outlet
NOTICE
The pedestal MUST be aligned with the backside of the
Ubeam.
3
Remove the protective cardboard and instruction sheet.
b
a
a
Protective cardboard
b
Instruction sheet
7.2.4
To prevent the outdoor unit from falling
over
In case the unit is installed in places where strong wind can tilt the
unit, take following measure:
1
Prepare 2 cables as indicated in the following illustration (field
supply).
2
Place the 2 cables over the outdoor unit.
3
Insert a rubber sheet between the cables and the outdoor unit
to prevent the cable from scratching the paint (field supply).
4
Attach the cable’s ends. Tighten those ends.
7.3
Mounting the indoor unit
7.3.1
To install the indoor unit
1
Lift the indoor unit from the pallet and place it on the floor.
120kg
4x
2
Slide the indoor unit into position.
3
Adjust the height of the leveling feet to compensate for floor
irregularities. The maximum allowed deviation is 1°.
≤1°