7
Technical data
7.1
Basic data
Tab. 7-1
Technical data control unit
Tab. 7-2
Technical data pump unit
Controller EKSR3PA
Dimensions W x T x H
230 x 815 x 142 cm
Operating voltage
230 V / 50 Hz
Control
Digital differential temperature regulator with plain text display
Max. electrical power consumption of the control
system
2 W
solar panel temperature sensor
Pt 1000
Storage tank and return flow temperature sensor
PTC
Feed temperature and flow sensor (optional)
EKSFLP12A
Pump unit EKSRDS1A
Dimensions W x T x H
240 x 410 x 130 cm
Operating voltage
230 V / 50 Hz
Solar panel circulation pump
Grundfos Solar 25-65 130
Max. electrical power consumption of the pump
52 W
Max. operating pressure
6 bar
Max. pump capacity
2 m³/h
Pressure gauge
0 - 10 bar
Temperature range
0 - 120 °C (short-term 160 °C)
Connections
4x 1 ¼" female for Ø 22 clamping ring bolt
Fig. 7-1
Connection assignment
CONF
Programming socket for software updates
FLS
FlowSensor EKSFLP12A (accessor
y)
TS
Storage temperature sensor t
S2
TR
Return flow temperature sensor
TK
Solar panel temperature sensor
BSK
Connection cable fo
r
solar priority
P1/P2
Solar panel circulation
pump P
S
F1
Fuse
Power
Power supply