Installation manual
3
EKHBRD011~Y1
Indoor unit for air to water heat pump system
4PW54465-1C
Application 2
Space heating and domestic hot water heating with one remote
controller installed with the unit, and another remote controller
installed in the living room.
The remote controller gives immediate feedback to the indoor unit
and by doing so it matches in a smart way the unit performance to
the demanded space heating requirements. In this way there is no
frequent start/stop of the unit or there are no too big temperature
fluctuations in the to be heated rooms. This remote controller has
also a smart logic functionality which controls the combined space
heating and domestic hot water demand (e.g. if room temperature
drops more than 3°C during domestic hot water operation, the unit
will automatically switch back to space heating). The main remote
controller (C1) is installed in the living room and can access all
settings (master). The second remote controller (C2) can not access
schedule and parameter settings (slave).
Refer to the chapter
"Electrical wiring work" on page 13
connecting the master and slave remote controller.
Application 3
Space heating and domestic hot water heating with a single remote
controller installed with the unit, and the external room thermostat
installed in the living room.
There is only a room thermostat on/off control. There is no smart
logic functionality for space heating. The domestic hot water
operation is performed according to the minimum and maximum
timer operation.
1
Outdoor unit
10
Collector (field supply)
2
Indoor unit
11
Radiator (field supply)
3
Refrigerant heat
exchanger
12
Electronic expansion valve
13
By-pass valve (field
supply)
4
Water heat exchanger
5
Compressor
C1
Remote controller (master)
6
Pump
C2
Optional remote controller
(slave)
7
Shut-off valve
8
Motorized 3-way valve
(optional)
A
Installation place
B
Living room
9
Domestic hot water tank
(optional)
Master
Slave
Operation ON/OFF
Operable
Operable
Domestic water heating operation ON/OFF
Operable
Operable
Setting the leaving water temperature
Operable
Operable
Setting the room temperature
Operable
Operable
Quiet mode ON/OFF
Operable
Operable
Weather dependent set point operation
ON/OFF
Operable
Operable
Setting the clock
Operable
Operable
Programming the schedule timer
Operable
—
Schedule timer operation ON/OFF
Operable
—
Field settings
Operable
—
Error code display
Operable
Operable
Test operation
Operable
Operable
Room thermostat functionality
Operable
—
10 13
C1
A
B
C2
7
4
3
12
12
2
1
8
6
5
M
11
9
Optionally the Daikin room thermostat EKRTR or EKRTW
can be connected to the Daikin system. Daikin can not
guarantee neither good operation nor reliability of the
system if another thermostat is used. For those reasons
Daikin can not give warranty of the system in such case.
1
Outdoor unit
10
Collector (field supply)
2
Indoor unit
11
Radiator (field supply)
3
Refrigerant heat exchanger
12
Electronic expansion
valve
4
Water heat exchanger
5
Compressor
13
By-pass valve (field
supply)
6
Pump
7
Shut-off valve
C1
Remote controller
8
Motorized 3-way valve
(optional)
T
Room thermostat
A
Installation place
9
Domestic hot water tank
(optional)
B
Living room
C1
7
4
3
12
12
2
1
8
6
5
M
11
9
10 13
T
A
B
Содержание EKHBRD-AY1