ESIE15-08
B
|
Pa
rt 5
.
Ap
pe
nd
ix
1.
Fi
el
d s
e
ttin
gs
Pag
e
140
19/07/16
Daikin
Alth
erma Mo
no
bl
oc CA
F
igu
re 25 - Fi
el
d setti
ng
s tabl
e
Breadcrumb
Field code
Setting name
Range, step
Default valu
e
Date
Value
User settings
Preset values
Room temperature
7.4.1.1
R/W
[3-07]~[3-06], step: A.3.2.4
21°C
7.4.1.2
R/W
[3-07]~[3-06], step: A.3.2.4
19°C
7.4.1.3
R/W
[3-08]~[3-09], step: A.3.2.4
24°C
7.4.1.4
R/W
[3-08]~[3-09], step: A.3.2.4
26°C
LWT main
7.4.2.1
[8-09]
R/W
[9-01]~[9-00], step: 1°C
45°C
7.4.2.2
[8-0A]
R/W
[9-01]~[9-00], step: 1°C
40°C
7.4.2.3
[8-07]
R/W
[9-03]~[9-02], step: 1°C
18°C
7.4.2.4
[8-08]
R/W
[9-03]~[9-02], step: 1°C
20°C
7.4.2.5
R/W
-10~10°C, step: 1°C
0°C
7.4.2.6
R/W
-10~10°C, step: 1°C
-2°C
7.4.2.7
R/W
-10~10°C, step: 1°C
0°C
7.4.2.8
R/W
-10~10°C, step: 1°C
2°C
Tank temperature
7.4.3.1
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
55°C
7.4.3.2
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
7.4.3.3
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
Quiet level
7.4.4
R/W
0: Level 1
1: Level 2
2: Level 3
Electricity price
7.4.5.1
[C-0C]
[D-0C]
R/W
0,00~990/kWh
0/kWh
7.4.5.2
[C-0D]
[D-0D]
R/W
0,00~990/kWh
0/kWh
7.4.5.3
[C-0E]
[D-0E]
R/W
0,00~990/kWh
0/kWh
Fuel price
7.4.6
R/W
0,00~990/kWh
0,00~290/MBtu
8,0/kWh
Set weather dependent
Main
Set
weather-dependent heating
7.7.1.1
[1-00]
Set weather-dependent heating
Low ambient temp. for LWT main zone heating
WD curve.
R/W
-40~5°C, step: 1°C
-10°C
7.7.1.1
[1-01]
Set weather-dependent heating
High ambient temp. for LWT main zone heating
WD curve.
R/W
10~25°C, step: 1°C
15°C
7.7.1.1
[1-02]
Set weather-dependent heating
Leaving water value for low ambient temp. for
LWT main zone heating WD curve.
R/W
[9-01]~[9-00]°C, step: 1°C
45°C
7.7.1.1
[1-03]
Set weather-dependent heating
Leaving water value for high ambient temp. for
LWT main zone heating WD curve.
R/W
[9-01]~min(45, [9-00])°C , step: 1°C
35°C
Set
weather-dependent cooling
7.7.1.2
[1-06]
Set weather-dependent cooling
Low ambient temp. for LWT main zone cooling
WD curve.
R/W
10~25°C, step: 1°C
20°C
7.7.1.2
[1-07]
Set weather-dependent cooling
High ambient temp. for LWT main zone cooling
WD curve.
R/W
25~43°C, step: 1°C
35°C
7.7.1.2
[1-08]
Set weather-dependent cooling
Leaving water value for low ambient temp. for
LWT main zone cooling WD curve.
R/W
[9-03]~[9-02]°C, step: 1°C
22°C
7.7.1.2
[1-09]
Set weather-dependent cooling
Leaving water value for high ambient temp. for
LWT main zone cooling WD curve.
R/W
[9-03]~[9-02]°C, step: 1°C
18°C
Additional
Set
weather-dependent heating
7.7.2.1
[0-00]
Set weather-dependent heating
Leaving water value for high ambient temp. for
LWT add zone heating WD curve.
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
7.7.2.1
[0-01]
Set weather-dependent heating
Leaving water value for low ambient temp. for
LWT add zone heating WD curve.
R/W
[9-05]~[9-06]°C, step: 1°C
45°C
7.7.2.1
[0-02]
Set weather-dependent heating
High ambient temp. for LWT add zone heating
WD curve.
R/W
10~25°C, step: 1°C
15°C
7.7.2.1
[0-03]
Set weather-dependent heating
Low ambient temp. for LWT add zone heating
WD curve.
R/W
-40~5°C, step: 1°C
-10°C
Set
weather-dependent cooling
7.7.2.2
[0-04]
Set weather-dependent cooling
Leaving water value for high ambient temp. for
LWT add zone cooling WD curve.
R/W
[9-07]~[9-08]°C, step: 1°C
8°C
7.7.2.2
[0-05]
Set weather-dependent cooling
Leaving water value for low ambient temp. for
LWT add zone cooling WD curve.
R/W
[9-07]~[9-08]°C, step: 1°C
12°C
7.7.2.2
[0-06]
Set weather-dependent cooling
High ambient temp. for LWT add zone cooling
WD curve.
R/W
25~43°C, step: 1°C
35°C
7.7.2.2
[0-07]
Set weather-dependent cooling
Low ambient temp. for LWT add zone cooling
WD curve.
R/W
10~25°C, step: 1°C
20°C
Installer settings
System layout
Standard
A.2.1.1
[E-00]
R/O
0~5
2: Monoblo
c
A.2.1.2
[E-01]
R/O
0~1
0: 8
A.2.1.3
[E-02]
R/O
0: Type 1 (*1)
1: T
yp
e 2
(*2
)
A.2.1.7
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
A.2.1.8
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
A.2.1.9
[F-0D]
R/W
0: Continuous
1: Sample
2: Re
q
ues
t
A.2.1.A
[E-04]
R/O
0: No
1: Yes
Field settings table
Installer setting at variance with
default value
Comfort (heating)
Eco (heating)
Comfort (cooling)
Eco (cooling)
Comfort (heating)
Eco (heating)
Comfort (cooling)
Eco (cooling)
Comfort (heating)
Eco (heating)
Comfort (cooling)
Eco (cooling)
Storage comfort
Storage eco
Reheat
High
Medium
Low
Unit type
Compressor type
Indoor software type
Unit control method
Number of LWT zones
Pump operation mode
Power saving possible
(*1) *B*_(*2) *D*
Breadcrumb
Field code
Setting name
Range, step
Default valu
e
Date
Value
Field settings table
Installer setting at variance with
default value
A.2.1.B
R/W
0: At unit
1: In room
A.2.1.C
[E-0D]
Glycol present
R/W
0: No
1: Yes
Options
A.2.2.A
[D-02]
R/W
0: No
1: Secondary rtrn
2: Disinf. shunt
A.2.2.B
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
Control box
A.2.2.E.1
[E-03]
R/W
0: No BUH
1: 1 step
2: 2 ste
p
s
A.2.2.E.2
[5-0D]
R/W
0~5
1: 1P,(1/1+2)
4: 3PN,(1/2)
5: 3PN,
(1/1+2
)
A.2.2.E.3
[D-01]
R/W
0: No
1: Active open
2: Active closed
A.2.2.E.4
[E-05]
R/W
0: No
1: Yes
A.2.2.E.5
[C-05]
R/W
1: Thermo ON/OFF
2: C/H re
q
uest
A.2.2.E.6
[C-06]
R/W
0~2
1: Thermo ON/OFF
Option box
A.2.2.F.1
[C-02]
R/W
0: No
1: Bivalent
2: -
3: -
A.2.2.F.2
[C-09]
R/W
0: Normally open
1: Normall
y
closed
A.2.2.F.3
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
A.2.2.F.4
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000
p
ulse/kWh
A.2.2.F.5
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
A.2.2.F.6
[D-04]
R/W
0: No
1: Yes
Capacities
A.2.3.1
[6-02]
R/W
0~10kW, step: 0,2kW
3
kW
A.2.3.2
[6-03]
R/W
0~10kW, step: 0,2kW
3kW
A.2.3.3
[6-04]
R/W
0~10kW, step: 0,2kW
0kW
Space operation
LWT settings
Main
A.3.1.1.1
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.1.2.1
[9-01]
Temperature range
Minimum temp (heating)
R/W
15~37°C, step: 1°C
25°C
A.3.1.1.2.2
[9-00]
Temperature range
Maximum temp (heating)
R/W
37~55°C, step: 1°C
55°C
A.3.1.1.2.3
[9-03]
Temperature range
Minimum temp (cooling)
R/W
5~18°C, step: 1°C
5°C
A.3.1.1.2.4
[9-02]
Temperature range
Maximum temp (cooling)
R/W
18~22°C, step: 1°C
22°C
A.3.1.1.5
[8-05]
R/W
0: No
1: Yes
A.3.1.1.7
[9-0B]
R/W
0: Quick
1: Slow
Additional
A.3.1.2.1
R/W
0: Fixed
1: Weather dep.
2: Fixed + scheduled
3: WD + scheduled
A.3.1.2.2.1
[9-05]
Temperature range
Minimum temp (heating)
R/W
15~37°C, step: 1°C
25°C
A.3.1.2.2.2
[9-06]
Temperature range
Maximum temp (heating)
R/W
37~55°C, step: 1°C
55°C
A.3.1.2.2.3
[9-07]
Temperature range
Minimum temp (cooling)
R/W
5~18°C, step: 1°C
5°C
A.3.1.2.2.4
[9-08]
Temperature range
Maximum temp (cooling)
R/W
18~22°C, step: 1°C
22°C
Delta
T source
A.3.1.3.1
[9-09]
R/W
3~10°C, step: 1°C
5°C
A.3.1.3.2
[9-0A]
R/W
3~10°C, step: 1°C
5°C
Room thermostat
A.3.2.1.1
[3-07]
Room temp. range
Minimum temp (heating)
R/W
12~18°C, step: A.3.2.4
16°C
A.3.2.1.2
[3-06]
Room temp. range
Maximum temp (heating)
R/W
18~30°C, step: A.3.2.4
30°C
A.3.2.1.3
[3-09]
Room temp. range
Minimum temp (cooling)
R/W
15~25°C, step: A.3.2.4
15°C
A.3.2.1.4
[3-08]
Room temp. range
Maximum temp (cooling)
R/W
25~35°C, step: A.3.2.4
35°C
A.3.2.2
[2-0A]
R/W
-5~5°C, step: 0,5°C
0°C
User interface location
DHW pump
External sensor
Booster heater
BUH: step 1
BUH: step 2
LWT setpoint mode
Modulated LWT
Emitter type
LWT setpoint mode
Heating
Cooling
Room temp. offset
Backup heater steps
BUH type
Preferential kWh rate
DHW operation
Contact type main
Contact type add.
Ext. backup heat src
Alarm output
External kWh meter 1
External kWh meter 2
External sensor
PCC by digital inputs
(*1) *B*_(*2) *D*