ESIE15-08B
|
Part 4. Maintenance
2. Maintenance procedures
19/07/16
Page 137
Daikin Altherma Monobloc CA
2.6. Draining the Domestic Hot Water tank
2.7. Anode
2.8. Descaling and chemical disinfection
Actions
Remarks
Refer to the Installation Manual of the installed DHW tank.
-
Actions
Remarks
Refer to the Installation Manual of the installed DHW tank.
-
Actions
Remarks
•
Depending on water quality and set temperature, scale can
deposit on the heat exchanger inside the domestic hot water
tank and can restrict heat transfer. For this reason, descaling
of the heat exchanger may be required at certain intervals.
•
If the applicable legislation requires a chemical disinfection in
specific situations, involving the domestic hot water tank,
please be aware that the domestic hot water tank is a
stainless steel cylinder containing an aluminium anode. We
recommend to use a non-chloride based disinfectant
approved for use with water intended for human consumption.
When using means for descaling or chemical disinfection, it must
be ensured that the water quality remains compliant with EU
directive 98/83 EC.