Parameter settings
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1420944 – 05/2014
Operating instructions
37
6.8 Rotary switch setting: Time Program
6.9 Rotary switch setting: Remote Param
Parameter
Designation
Access
Setting range
Min / Max
Factory
setting
Incre-
ment
BE
HF
Party
The heating circuit operates at the target room temperature set in the [T-Room 1 Setpoint] pa-
rameter for the set period of time. If the [Automatic 1] or [Automatic 2] timer programmes are
active, the heating cycle is extended or started early. (Target room temperature - see
section 3.4.7).
The hot water generation is not affected.
E
E
00:00 - 06:00
00:00
1 h
Away
The heating circuit operates at the target room temperature set in the [T-Absence] parameter
for the set period of time.
The hot water generation is not affected.
E
E
00:00 - 06:00
00:00
1 h
Vacation
The heating circuit operates at the target room temperature set in the [T-Absence] parameter
permanently (24 h per day).
A calendar function can be used to enter a time period for the absence.
E
E
Date on first
day
-
Date on last
day
-
1 Day
Holiday
A calendar function can be used to enter a time period for presence.
During this time, the system operates exclusively in accordance with the "Sunday" settings in
[DHW Program 1] and [HC Program 1].
E
E
Date on first
day
-
Date on last
day
-
1 Day
HC Program 1
In this menu we can parametrise the 1st timer programme for the heating circuit. 3 switching
cycles with a resolution of 15 minutes can be set. A separate entry for each weekday is possi-
ble. Format: (On) hh:mm - hh:mm (Off)
Also, the cycles can be parametrised from Monday to Friday, Saturday to Sunday and Monday
to Sunday.
E
E
see
chapter 3.4.7
see
tab. 3-8
15 min
HC Program 2
In this menu we can parametrise the 2nd timer programme for the heating circuit. 3 switching
cycles with a resolution of 15 minutes can be set. A separate entry for each weekday is possi-
ble. Format: (On) hh:mm - hh:mm (Off)
Also, the cycles can be parametrised from Monday to Friday, Saturday to Sunday and Monday
to Sunday.
E
E
see
chapter 3.4.7
see
tab. 3-8
15 min
DHW Program 1
In this menu we can parametrise the 1st timer programme for hot water generation. 3 switching
cycles with a resolution of 15 minutes can be set. A separate entry for each weekday is possi-
ble. Format: (On) hh:mm - hh:mm (Off)
Also, the cycles can be parametrised from Monday to Friday, Saturday to Sunday and Monday
to Sunday.
E
E
see
chapter 3.4.7
see
tab. 3-8
15 min
DHW Program 2
In this menu we can parametrise the 2nd timer programme for hot water generation. 3 switch-
ing cycles with a resolution of 15 minutes can be set. A separate entry for each weekday is
possible. Format: (On) hh:mm - hh:mm (Off)
Also, the cycles can be parametrised from Monday to Friday, Saturday to Sunday and Monday
to Sunday.
E
E
see
chapter 3.4.7
see
tab. 3-8
15 min
Circulation Time
In this menu we can parametrise a timer programme for the circulation pump. 3 switching cy-
cles with a resolution of 15 minutes can be set. A separate entry for each weekday is possible.
Format: (On) hh:mm - hh:mm (Off)
Also, the cycles can be parametrised from Monday to Friday, Saturday to Sunday and Monday
to Sunday.
E
E
see
chapter 3.4.7
see
tab. 3-8
15 min
Tab. 6-10 Parameter in rotary switch setting "Time Program"
Parameter
Description
Access
Setting range
Min / Max
Factory
setting
Incre-
ment
BE
HF
Bus - Scan
Off: No function
On: Controller checks which RoCon devices are connected to the system using the CAN bus
lines. Devices that are detected are displayed with their type and data bus address (for example:
MM#8 = mixer module with data bus address 8).
The selection and activation of a device with the rotary switch switches the function of the control
unit to that of the selected device (see chapter 3.4.9).
E
E
Off
On
Off
-
No selection
Activation switches to the local device.
E
E
-
Contr BM1/BE1 #X
Activation switches to the Daikin Altherma EHS(X/H) with the bus ID X.
E
E
-
Mix Valve #X
Activation switches to the mixer module with the bus ID X.
E
E
-
Tab. 6-11 Parameter in rotary switch setting "Remote Param"