Operating instructions
22
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1420944 – 05/2014
3
x
Operation
●
Select the
"Setup"
level with the rotary switch.
An overview is displayed.
●
Use the rotary switch to select and confirm the [Language],
[Date] or [Time] parameters.
●
Select and change the value to be changed within the
individual display using the rotary switch.
●
Confirm the changes with a brief push of the rotary switch.
Change has been accepted. Jump back to previous dis-
play.
More detailed explanations and possible setting values for this rotary switch setting
can be seen in section 3.6 and in chapter 6.2.
3.4.9 Terminal function
In the rotary switch setting
"Remote Param"
, if terminal
mode is activated, other controllers in the RoCon system can also
be parameterised via the controller integrated in the CAN bus.
After activation of the "Bus - Scan" a list of the equipment that
was recognised is shown for selection in the display (external
equipment and local equipment).
After selection and acknowledgement of an external item of
equipment, this is shown on the local Controller. The local control
element acts as the remote control for the external equipment. In
this case all the control functions are provided and saved 1:1 as
on the external equipment.
During this terminal function the header of the display carries ad-
ditional information on the remotely controlled equipment; the
symbol
#X indicates the bus ID setting for the remotely con-
trolled equipment.
The displayed values and symbols are always loaded from the
selected equipment (such as the mixer circuit infeed temperature
of the mixer module EHS157068).
For operation of the local equipment, this must be activated again
in the selection list (parameter [No selection]).
Activating / Deactivating normal operation
Requirement: A valid terminal address is assigned to the
RoCon B1 control element of the Daikin Altherma EHS(X/H) or
the EHS157034 room station.
●
Use the rotary switch to select the parameter [New scan?]
and confirm with "Yes".
Bus - Scan is performed.
An overview of all the equipment found is displayed.
●
Use the rotary switch to select the equipment for which the
terminal function is to be performed.
●
Confirm the changes with a brief push of the rotary switch.
The local control element acts as the remote control for
the external equipment.
To
end
terminal mode
and restore operation of the assigned
equipment to the control element, at the
level "
Remote Param
"
the
parameter [No selection]
must be selected and acknowl-
edged
(see fig. 3-10).
Fig. 3-9
Display example for a remotely controlled mixer module
If the message "n. A." is displayed at rotary switch set-
ting
, the control unit has yet to be assigned a valid
terminal address.
If the message "n. A." is still displayed it may be nec-
essary to update the device software before the ter-
minal function can be used. Contact the Daikin Service
Team in such cases.
The terminal address can be set only after the Techni-
cian password has been input. Contact your specialist
heating technician in this regard.
●
Place the rotary switch in
the
"Remote Param"
position.
The level "
Remote
Param
" is displayed.
●
Select the parameter
[Bus - Scan] with the
rotary switch.
●
Confirm the changes with
a brief press of the rotary
switch.
The context menu is
displayed.
Fig. 3-10 Display of the level "Re-
mote Param" at commis-
sioning or temporary
disconnection from the
mains
Remote Param
Bus - Scan
No selection