Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
A.8
[D-01]
R/W
0~3
0: No
1: Open tariff
2: Closed tariff
A.8
[D-02]
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
A.8
[D-03]
R/W
0: Disabled
1: Enabled, shift 2°C (from -2 to 2°C)
2: Enabled, shift 4°C (from -2 to 2°C)
3: Enabled, shift 2°C (from -4 to 4°C)
4: Enabled, shift 4°C (from -4 to 4°C)
A.8
[D-04]
R/O
0: No
1: Yes
A.8
[D-05]
R/W
0: Forced off
1: As normal
A.8
[D-07]
0
A.8
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.8
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.8
[D-0A]
0
A.8
[D-0B]
2
A.8
[D-0C]
R/W
0~49
0
A.8
[D-0D]
R/W
0~49
0
A.8
[D-0E]
R/W
0~49
0
A.8
[E-00]
R/O
0~5
2: Monobloc
A.8
[E-01]
R/O
0~1
1: 16
A.8
[E-02]
R/O
0: Type 1 (*1)
1: Type 2 (*2)
A.8
[E-03]
R/W
0: No BUH
1: 1 step
2: 2 steps
A.8
[E-04]
R/O
0~1
0: No
A.8
[E-05]
R/W
0: No
1: Yes
A.8
[E-06]
1
A.8
[E-07]
0: EKHWS
5: EKHWP
A.8
[E-08]
R/W
0: Disabled
1: Enabled
A.8
[E-09]
0
A.8
[E-0A]
0
A.8
[E-0B]
0
A.8
[E-0C]
0
A.8
[E-0D]
R/W
0: No
1: Yes
A.8
[E-0E]
0
A.8
[F-00]
R/W
0: Disabled
1: Enabled
A.8
[F-01]
R/W
10~35°C, step: 1°C
20°C
A.8
[F-02]
3
A.8
[F-03]
5
A.8
[F-04]
0
A.8
[F-05]
0
A.8
[F-06]
0
A.8
[F-09]
R/W
0: Disabled
1: Enabled
A.8
[F-0A]
0
A.8
[F-0B]
0
A.8
[F-0C]
1
A.8
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
Forced off contact type
What type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
Is the option box used for PCC ?
Is the pump allowed to run if prefer. kWh rate PS is cut?
--
Is an external kWh meter used for power measurement?
Is an external kWh meter used for power measurement?
--
--
What is the high electricity price (Do not use)
What is the medium electricity price (Do not use)
What is the low electricity price (Do not use)
Which type of unit is installed?
Which type of compressor is installed?
What is the indoor unit software type?
What is the number of backup heater steps?
Is the power saving function available on the outdoor unit?
Can the system prepare domestic hot water?
--
What kind of DHW tank is installed?
Power saving function for outdoor unit.
--
--
--
--
Pump operation allowed outside range.
Above which outdoor temperature is cooling allowed?
--
--
Is the system filled with glycol ?
--
--
What is the pump operation mode?
--
--
--
--
Pump operation during flow abnormality.
--
4P522033-1 - 2018.01
(*1) *B*_(*2) *D*