4/9
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
└────────────────── Delta T source
A.3.1.3.1
[9-09]
R/W
3~10°C, step: 1°C
5°C
A.3.1.3.2
[9-0A]
R/W
3~10°C, step: 1°C
5°C
└─ Room thermostat
A.3.2.1.1
[3-07]
Room temp. range
Minimum temp (heating)
R/W
12~18°C, step: A.3.2.4
16°C
A.3.2.1.2
[3-06]
Room temp. range
Maximum temp (heating)
R/W
18~30°C, step: A.3.2.4
30°C
A.3.2.1.3
[3-09]
Room temp. range
Minimum temp (cooling)
R/W
15~25°C, step: A.3.2.4
15°C
A.3.2.1.4
[3-08]
Room temp. range
Maximum temp (cooling)
R/W
25~35°C, step: A.3.2.4
35°C
A.3.2.2
[2-0A]
R/W
-5~5°C, step: 0,5°C
0°C
A.3.2.3
[2-09]
R/W
-5~5°C, step: 0,5°C
0°C
A.3.2.4
R/W
0: 0,5 °C
1: 1 °C
└─ Operation range
A.3.3.1
[4-02]
R/W
14~35 °C, step: 1°C
3
5°C
A.3.3.2
[F-01]
R/W
10~35°C, step: 1°C
20°C
└─ Domestic hot water (DHW)
└─ Type
A.4.1
[6-0D]
R/W
0: Reheat only
1: Scheduled
2: Scheduled only
└─ Disinfection
A.4.4.1
[2-01]
R/W
0: No
1: Yes
A.4.4.2
[2-00]
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
A.4.4.3
[2-02]
R/W
0~23 hour, step: 1 hour
23
A.4.4.4
[2-03]
R/W
55~75°C, step: 5°C
70°C
A.4.4.5
[2-04]
R/W
5~60 min, step: 5 hour
10
└─ Maximum set point
A.4.5
[6-0E]
R/W
If [E-07]=0
40~75°C, step: 1°C
60°C
If [E-07]=5
40~80°C, step: 1°C
80°C
└─ SP mode
A.4.6
[2-01]
R/W
0: Fixed
1: Weather dep.
└─ Weather dependent curve
A.4.7
[0-0B]
R/W
35~[6-0E]°C, step: 1°C
55°C
A.4.7
[0-0C]
R/W
45~[6-0E]°C, step: 1°C
60°C
A.4.7
[0-0D]
R/W
10~25°C, step: 1°C
15°C
A.4.7
[0-0E]
R/W
-40~5°C, step: 1°C
-10°C
└─ Heat sources
└─ Backup heater
A.5.1.1
[4-00]
R/W
0~2
0: Disabled
1: Enabled
A.5.1.3
[4-07]
R/W
0: No
1: Yes
A.5.1.4
[5-01]
R/W
-15~35°C, step: 1°C
-4°C
└─ System operation
└─ Auto restart
A.6.1
[3-00]
R/W
0: No
1: Yes
└─ Preferential kWh rate
A.6.2.1
[D-00]
R/W
0~3
0: None
1: BSH only
2: BUH only
3: All heaters
A.6.2.2
[D-05]
R/W
0: Forced off
1: As normal
└─ Averaging time
A.6.4
[1-0A]
R/W
0: No averaging
1: 12 hours
2: 24 hours
3: 48 hours
4: 72 hours
└─ Ext amb. sensor offset
A.6.5
[2-0B]
R/W
-5~5°C, step: 0,5°C
0°C
Heating
Cooling
Room temp. offset
Ext. room sensor offset
Room temp. step
Weather-dependent curve
Space heating OFF temp
Space cooling On temp
Weather-dependent curve
Operation mode
Weather-dependent curve
Disinfection
Enable BUH step 2
Equilibrium temp.
Start time
Temperature target
Duration
Operation day
Weather-dependent curve
Allowed heaters
Forced pump OFF
4P522033-1 - 2018.01
(*1) *B*_(*2) *D*