8 Configuration
Installation and operation manual
25
EHYKOMB33A
Daikin Altherma hybrid heat pump – gas boiler module
4P353067-1K – 2020.10
2
Tilt the bottom side of the front panel towards the gas boiler.
3
Screw both screws of the cover.
4
Close the display cover.
7.8.2
To install the cover plate
The boiler cover plate is an optional product.
8
Configuration
8.1
Gas boiler
8.1.1
Overview: Configuration
1
2
7
5 6
3 4
8
a
b
c
f
e
d
Read out
1
On/OFF
2
Main display
3
Space heating operation
4
Domestic hot water operation
5
Domestic hot water comfort function eco
6
Domestic hot water comfort function on (continuous)
7
Service display
8
Flashes to indicate a fault
Operation
a
On/OFF button
b
One single room
c
button
d
button
e
Service button
f
Reset button
8.1.2
Basic configuration
To turn on/off the gas boiler
1
Push the button.
Result:
The green LED above the button will light up when the
boiler is ON.
When the gas boiler is OFF, is displayed on the service display to
indicate that the power is ON. In this mode, the pressure in the
space heating installation will also be displayed on the main display
(bar).
Domestic hot water comfort function
Not applicable for Switzerland
This function can be operated with the domestic hot water comfort
key (
). The following functions are available:
▪ On: The LED lights up. The domestic hot water comfort function
is switched on. The heat exchanger will be kept on temperature to
assure instant delivery of hot water.
▪ Eco: The
LED lights up. The domestic hot water comfort
function is self-learning. The appliance will learn to adapt to the
pattern of use of hot tap water. For example: the temperature of
the heat exchanger will NOT be maintained during the night or in
case of long absence.
▪ Off: Both LED's are OFF. The temperature of the heat exchanger
is NOT maintained. For example: It will take a while to deliver hot
water to the hot water taps. If there is no need for immediate hot
water delivery, the domestic hot water comfort function can be
turned off.
To reset the gas boiler
INFORMATION
Resetting is only possible when an error occurs.
Prerequisite:
Flashing LED above the
button and an error code