7 Installation
Installation and operation manual
19
EHYKOMB33A
Daikin Altherma hybrid heat pump – gas boiler module
4P353067-1K – 2020.10
INFORMATION
All piping lengths in the tables below are maximum
equivalent piping lengths.
1
L1
L1
L2
L1
3
2
C
53
C
93
C
13
C
33
L2
4
L1
INFORMATION
The above installation examples are just examples and
can differ on some details.
Explanation of the flue systems
Category in accordance with CE
C
13
Horizontal flue system. Discharge in the outside wall. Inlet
opening for the air supply is in the same pressure zone as the
discharge.
For example: a wall terminal through the façade.
C
33
Vertical flue system. Flue gas discharge via the roof. Inlet
opening for the air supply is in the same pressure zone as the
discharge.
For example: a vertical roof terminal.
C
43
Joint air supply and flue gas discharge duct (CLV system).
Twin pipe or concentric.
—
C
53
Separate air supply and separate flue gas discharge duct.
Discharge into different pressure zones.
—
C
63
Free in the market available flue material with CE approval.
Do NOT mix flue materials from different suppliers.
C
83
Joint air supply and flue gas discharge duct (CLV system).
Discharging into different pressure zones.
Only as twin pipe system.
C
93
Air supply and flue gas discharge duct in shaft or ducted:
concentric. Air supply from existing duct. Flue gas discharge
via the roof. Air supply and flue gas discharge are in the same
pressure zone.
Concentric flue system between the gas boiler and the duct.
The horizontal flue MUST be installed under a 3° fall towards the
boiler (50 mm per metre) and MUST be supported with a minimum
of 1 bracket at each meter length. Best recommended position of the
bracket is just before the joint.
INFORMATION
Flexible flue gas lines may NOT be used in horizontal
connection sections.
C
13
(1)
C
33
(2)
C
13
(1)
C
33
(2)
60/100
60/100
Twin-80
Twin-80
L1 (m)
L1 (m)
L1 (m)
L1 (m)
10
10
80
21
C
13
(1)
C
33
(2)
C
93
(4)
C
53
(3)
80/125
80/125
80/125
80
60/100
60
L1 (m)
L1 (m)
L1 (m)
L2 (m)
L1 (m)
L2 (m)
29
29
10
25
6
1
1
10
Special remark regarding
C
53
:
The maximum lengths for L1 and L2
are related to each other. First determine the length of L1; then
make use of the graph below to determine the maximum length of
L2. For example: if the length of L1 is 2 m, L2 can maximally be 8 m
long.