3/8
Breadcrumb
Field code
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
Setting name
A.2.1.8
[7-02]
R/W
0: 1 LWT zone
1: 2 LWT zones
A.2.1.9
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
A.2.1.A
[E-04]
R/O
1: Yes
A.2.1.B
R/W
0: At unit
1: In room
└─
Options
A.2.2.1
[E-05]
R/W
0: No
1: Yes
A.2.2.2
[E-06]
R/W
0: No
1: Yes
A.2.2.3
[E-07]
R/W
0~6
4: Type 5
6: Type 7
A.2.2.4
[C-05]
R/W
1: Thermo ON/OFF
2: C/H request
A.2.2.5
[C-06]
R/W
1: Thermo ON/OFF
2: C/H request
A.2.2.6.2
[D-07]
Digital I/O PCB
Solar kit
R/W
0: No
1: Yes
A.2.2.6.3
[C-09]
Digital I/O PCB
Alarm output
R/W
0: Normally open
1: Normally closed
A.2.2.7
[D-04]
R/W
0: No
1: Pwr consmp ctrl
A.2.2.8
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
A.2.2.A
[D-02]
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circul. Pump
4: CP & disinf. Sh
A.2.2.B
[C-08]
R/W
0: No
1: Outdoor sensor
2: Room sensor
A.2.2.C
[D-0A]
R/W
0: Not present
1: 1 /m³
2: 10 /m³
3: 100 /m³
└─
Space operation
└─
LWT settings
└──────────────────
Main
A.3.1.1.1
R/W
0: Fixed
1: Weather dep.
2: Fixed / scheduled
3: WD / scheduled
A.3.1.1.2.1
[9-01]
Temperature range
Minimum temp (heating)
R/W
15~37°C, step: 1°C
25°C
A.3.1.1.2.2
[9-00]
Temperature range
Maximum temp (heating)
R/W
37~80°C, step: 1°C
80°C
A.3.1.1.2.3
[9-03]
Temperature range
Minimum temp (cooling)
R/W
5~18°C, step: 1°C
5°C
A.3.1.1.2.4
[9-02]
Temperature range
Maximum temp (cooling)
R/W
18~22°C, step: 1°C
22°C
A.3.1.1.5
[8-05]
R/W
0: No
1: Yes
A.3.1.1.6.1
[F-0B]
Shut-off valve
Thermo On/OFF
R/W
0: No
1: Yes
A.3.1.1.6.2
[F-0C]
Shut-off valve
Cooling
R/W
0: No
1: Yes
A.3.1.1.7
[9-0B]
R/W
0: Quick
1: Slow
└──────────────────
Additional
A.3.1.2.1
R/W
0: Fixed
1: Weather dep.
2: Fixed / scheduled
3: WD / scheduled
A.3.1.2.2.1
[9-05]
Temperature range
Minimum temp (heating)
R/W
15~37°C, step: 1°C
25°C
A.3.1.2.2.2
[9-06]
Temperature range
Maximum temp (heating)
R/W
37~80°C, step: 1°C
80°C
A.3.1.2.2.3
[9-07]
Temperature range
Minimum temp (cooling)
R/W
5~18°C, step: 1°C
5°C
A.3.1.2.2.4
[9-08]
Temperature range
Maximum temp (cooling)
R/W
18~22°C, step: 1°C
22°C
└─
Room thermostat
A.3.2.1.1
[3-07]
Room temp. range
Minimum temp (heating)
R/W
12~18°C, step: A.3.2.4
12°C
A.3.2.1.2
[3-06]
Room temp. range
Maximum temp (heating)
R/W
18~30°C, step: A.3.2.4
30°C
A.3.2.1.3
[3-09]
Room temp. range
Minimum temp (cooling)
R/W
15~25°C, step: A.3.2.4
15°C
A.3.2.1.4
[3-08]
Room temp. range
Maximum temp (cooling)
R/W
25~35°C, step: A.3.2.4
35°C
A.3.2.2
[2-0A]
R/W
-5~5°C, step: 0,5°C
0°C
A.3.2.3
[2-09]
R/W
-5~5°C, step: 0,5°C
0°C
A.3.2.4
R/W
0: 1°C
1: 0,5°C
└─
Operation range
A.3.3.1
[4-02]
R/W
14~35°C, step: 1°C
25°C
A.3.3.2
[F-01]
R/W
10~35°C, step: 1°C
20°C
└─
Domestic hot water (DHW)
└─
Type
A.4.1
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
Number of LWT zones
Pump operation mode
Power saving possible
User interface location
DHW operation
DHW tank
DHW tank type
Contact type main
Contact type add.
Demand PCB
External kWh meter 1
DHW pump
External sensor
External gas meter
LWT setpoint mode
Modulated LWT
Emitter type
LWT setpoint mode
Room temp. offset
Ext. room sensor offset
Room temp. step
Space heating OFF temp
Space cooling On temp
4P353731-1J - 2022.09