9 Installation
Installer reference guide
43
EJHA EHY32AA
Daikin Altherma Hybrid hydrosplit heat pump
4P531180-1 – 2018.06
1N~ 50 Hz
220-240 V
PE
N
L
Q1DI
1
2
3
L
N
X2M
1×
a
3×
a
Recommended field fuse: 20 A
Q1DI
Earth leakage circuit breaker
2
Fix the cable with cable ties to the cable tie mountings.
To connect the user interface
#
Action
1
Connect the user interface cable to the outdoor unit.
Fix the cable with cable ties to the cable tie mountings.
1
2
P1
P2
X5M
1×
a
a
User interface. The user interface is required for
operation, but has to be ordered separately (mandatory
option).
2
Insert a screwdriver into the slots underneath the user
interface and carefully separate the faceplate from the
wallplate.
The PCB is mounted in the faceplate of the user interface.
Be careful NOT to damage it.
3
Fix the wallplate of the user interface to the wall.
4
Connect as shown in 4A, 4B, 4C or 4D.
#
Action
5
Reinstall the faceplate onto the wallplate.
Be careful NOT to pinch the wiring when attaching the
frontplate to the unit.
4A From the rear
b
a
PCB
1×
4B From the left
a
PCB
b
1×
4C From the top
a
b
PCB
b
1×
4D From the top centre
a
PCB
b
b
1×
a
Notch this part for the wiring to pass through with nippers
etc.
b
Secure the wiring to the front part of the casing using the
wiring retainer and clamp.
To connect the dedicated gas boiler to the outdoor
unit
1
Connect the interconnection cable between outdoor unit and
gas boiler to the appropriate terminals as shown in the
illustration below. The interconnection cable is field supplied.
A2P
X10A
X5M/3
X5M/4
1 2
a
3
4
X5M
1×
a
EHY32AA gas boiler
2
Fix the cable with cable ties to the cable tie mountings.
To connect the domestic hot water pump
1
Connect the domestic hot water pump cable to the appropriate
terminals as shown in the illustration below.
Содержание Altherma EHY2KOMB28AA
Страница 112: ...4P531180 1 2018 06 Copyright 2018 Daikin ...