1 About this document

2

2 User safety instructions

3

2.1

General......................................................................................

3

2.2

Instructions for safe operation ...................................................

3

3 About the system

4

3.1

Components in a typical system layout .....................................

4

4 Quick guide

4

4.1

User permission level ................................................................

4

4.2

Space heating/cooling ...............................................................

5

4.3

Domestic hot water....................................................................

6

5 Operation

6

5.1

User interface: Overview ...........................................................

6

5.2

Menu structure: Overview user settings ....................................

8

5.3

Possible screens: Overview ......................................................

9

5.3.1

Home screen...............................................................

9

5.3.2

Main menu screen ...................................................... 10

5.3.3

Setpoint screen ........................................................... 10

5.3.4

Detailed screen with values ........................................ 11

5.4

Turning operation ON or OFF ...................................................

11

5.4.1

Visual indication .......................................................... 11

5.4.2

To turn ON or OFF...................................................... 11

5.5

Reading out information ............................................................

12

5.6

Space heating/cooling control ...................................................

12

5.6.1

Setting the space operation mode .............................. 12

5.6.2

To change the desired room temperature................... 12

5.6.3

To change the desired leaving water temperature...... 13

5.7

Domestic hot water control ........................................................

13

5.7.1

Reheat mode .............................................................. 13

5.7.2

Scheduled mode ......................................................... 13

5.7.3

Sch reheat mode........................................... 13

5.7.4

Using DHW powerful operation................................... 14

5.8

Schedule screen: Example........................................................

14

5.9

Weather-dependent curve.........................................................

16

5.9.1

What is a weather-dependent curve? ......................... 16

5.9.2

2-points curve ............................................................. 16

5.9.3

Slope-offset curve ....................................................... 16

5.9.4

Using weather-dependent curves ............................... 17

6 Energy saving tips

18

7 Maintenance and service

18

7.1

Overview: Maintenance and service .........................................

18

8 Troubleshooting

18

8.1

To display the help text in case of a malfunction.......................

19

8.2

To check the malfunction history...............................................

19

8.3

Symptom: You are feeling too cold (hot) in your living room.....

19

8.4

Symptom: The water at the tap is too cold ................................

19

8.5

Symptom: Heat pump failure .....................................................

19

8.6

Symptom: The system is making gurgling noises after
commissioning...........................................................................

20

9 Disposal

20

10 Glossary

20

11 Installer settings: Tables to be filled in by

installer

20

11.1

Configuration wizard..................................................................

20

11.2

Settings menu ...........................................................................

20

1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Request the installer to inform you about the settings that he used

to  configure  your  system.  Check  if  he  has  filled  in  the  installer
settings tables. If not, request him to do so.

▪ Keep the documentation for future reference.

Target audience

End users

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the outdoor unit)

Operation manual:

▪ Quick guide for basic usage

▪ Format: Paper (in the box of the outdoor unit)

User reference guide:

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installer reference guide:

▪ Preparation  of  the  installation,  good  practices,  reference

data, …

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Addendum book for optional equipment:

▪ Additional info about how to install optional equipment

▪ Format: Paper (in the box of the outdoor unit) + Digital files on

http://www.daikineurope.com/support-and-manuals/product-
information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

Daikin Residential Controller app

If set up by your installer, you can use the
Daikin Residential Controller app to control and
monitor the status of your system. For more
information, see:

http://www.onlinecontroller.daikineurope.com/

Breadcrumbs

Breadcrumbs  (example: 

[4.3]

)  help  you  to  locate  where  you  are  in

the menu structure of the user interface.

Содержание Altherma 3 M Series

Страница 1: ...Operation manual Daikin Altherma 3 M English Operation manual Daikin Altherma 3 M EBLA09 16DAV3 EBLA09 16DAW1 EBLA09 16DA3V3 EBLA09 16DA3W1 EDLA09 16DAV3 EDLA09 16DAW1 EDLA09 16DA3V3 EDLA09 16DA3W1...

Страница 2: ...wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible perf...

Страница 3: ...unit CAUTION Do NOT place any objects or equipment on top of the unit Do NOT sit climb or stand on the unit Units are marked with the following symbol This means that electrical and electronic product...

Страница 4: ...nd subsequently into the room when you purge air from the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a space Cool down a space Produce domesti...

Страница 5: ...2 2 Set operation to On or Off To change the desired room temperature During room temperature control you can use the room temperature setpoint screen to read out and adjust the desired room temperat...

Страница 6: ...mation see also 5 4 Turning operation ON or OFF 411 5 6 Space heating cooling control 412 5 8 Schedule screen Example 414 5 9 Weather dependent curve 416 User reference guide 4 3 Domestic hot water To...

Страница 7: ...min of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens the display Dials and buttons You use the dials and buttons To navigate through the...

Страница 8: ...4 Quiet Activation Schedule Level 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 4 Space heating cooling Operation mode Operation mode schedule Room comfort setpoin...

Страница 9: ...ive Powerful operation mode active c Emergency Heat pump failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available vi...

Страница 10: ...in zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temp...

Страница 11: ...e home screen will be greyed out Room temperature control 1 6 bar 55 21 35 45 a 1 6 bar 55 21 35 45 b a Room temperature control ON b Room temperature control OFF Space heating cooling operation 1 6 b...

Страница 12: ...pace You have to tell the system which operation mode to use To tell the system which space operation to use you can You can Location Check which space operation mode is currently used Home screen Set...

Страница 13: ...the DHW tank mode is reheat the risk for capacity shortage and comfort problem is significant In case of frequent reheat operation space heating cooling function is regularly interrupted 5 7 2 Schedu...

Страница 14: ...This example shows how to set a room temperature schedule in heating mode for the main zone INFORMATION The procedures to program other schedules are similar To program the schedule overview Example Y...

Страница 15: ...Tue Sun User defined 1 C 4 Select Paste Delete Edit Copy Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C 5 Repeat this action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined...

Страница 16: ...g Additional zone Cooling Tank only available to installers INFORMATION To operate weather dependent correctly configure the setpoint of the main zone additional zone or tank See 5 9 4 Using weather d...

Страница 17: ...to setpoint mode Set the setpoint mode to 3 4 Additional zone Setpoint mode WD heating fixed cooling OR Weather dependent Additional zone Cooling 3 4 Additional zone Setpoint mode Weather dependent T...

Страница 18: ...sary Example In the morning and evening 7 Maintenance and service 7 1 Overview Maintenance and service The installer has to perform a yearly maintenance You can find the contact helpdesk number via th...

Страница 19: ...consumes extra energy See 5 7 4 Using DHW powerful operation 414 If the problems recurs daily do one of the following Increase the DHW tank temperature preset value See the user reference guide Adjust...