3 About the system

Operation manual

4

EBLA09~16DA + EDLA09~16DA

Daikin Altherma 3 M

4P620243-1 – 2020.06

WARNING

▪ Do NOT pierce or burn refrigerant

cycle parts.

▪ Do NOT use cleaning materials or

means to accelerate the defrosting
process other than those
recommended by the manufacturer.

▪ Be aware that the refrigerant inside

the system is odourless.

WARNING

The refrigerant inside the unit is mildly
flammable, but normally does NOT
leak. If the refrigerant leaks in the room
and comes in contact with fire from a
burner, a heater, or a cooker, this may
result in fire, or the formation of a
harmful gas.

Turn off any combustible heating
devices, ventilate the room, and
contact the dealer where you
purchased the unit.

Do NOT use the unit until a service
person confirms that the part from
which the refrigerant leaked has been
repaired.

WARNING

Air purging heat emitters or
collectors.

 Before you purge air from

heat emitters or collectors, check if 
or 

 is displayed on the home screen

of the user interface.

▪ If not, you can purge air immediately.

▪ If yes, make sure that the room

where you want to purge air is
sufficiently ventilated. 

Reason:

Refrigerant might leak into the water
circuit, and subsequently into the
room when you purge air from the
heat emitters or collectors.

3

About the system

Depending on the system layout, the system can:

▪ Heat up a space

▪ Cool down a space

▪ Produce domestic hot water (if a DHW tank is installed)

INFORMATION

Cooling is only applicable in case of reversible models.

INFORMATION

If  underfloor  heating  is  installed  in  the  main  zone,  then  in
cooling mode the main zone can only provide refreshment.
Real cooling is then NOT allowed.

3.1

Components in a typical system
layout

c

A

f

a

b

e

d

B

C

A

Main zone. 

Example: 

Living room.

B

Additional zone. 

Example: 

Bedroom.

C

Technical room. 

Example: 

Garage.

a

Outdoor unit heat pump

b

Underfloor heating

c

Heat pump convectors or fan coil units

d

User interface

e

Dedicated Human Comfort Interface (BRC1HHDA used as
room thermostat)

f

Domestic hot water (DHW) tank

4

Quick guide

4.1

User permission level

The  amount  of  information  you  can  read  out  and  edit  in  the  menu
structure depends on your user permission level:

User

: Standard mode

Advanced user

: You can read out and edit more information

To change the user permission level

1

Go to [B]: 

User profile

.

User profile

B

2

Enter the applicable pin code for the user permission
level.

▪ Browse  through  the  list  of  digits  and  change  the

selected digit.

▪ Move the cursor from left to right.

▪ Confirm the pin code and proceed.

User pin code

The 

User

 pin code is 

0000

.

Содержание Altherma 3 M Series

Страница 1: ...Operation manual Daikin Altherma 3 M English Operation manual Daikin Altherma 3 M EBLA09 16DAV3 EBLA09 16DAW1 EBLA09 16DA3V3 EBLA09 16DA3W1 EDLA09 16DAV3 EDLA09 16DAW1 EDLA09 16DA3V3 EDLA09 16DA3W1...

Страница 2: ...wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best possible perf...

Страница 3: ...unit CAUTION Do NOT place any objects or equipment on top of the unit Do NOT sit climb or stand on the unit Units are marked with the following symbol This means that electrical and electronic product...

Страница 4: ...nd subsequently into the room when you purge air from the heat emitters or collectors 3 About the system Depending on the system layout the system can Heat up a space Cool down a space Produce domesti...

Страница 5: ...2 2 Set operation to On or Off To change the desired room temperature During room temperature control you can use the room temperature setpoint screen to read out and adjust the desired room temperat...

Страница 6: ...mation see also 5 4 Turning operation ON or OFF 411 5 6 Space heating cooling control 412 5 8 Schedule screen Example 414 5 9 Weather dependent curve 416 User reference guide 4 3 Domestic hot water To...

Страница 7: ...min of non interaction with the user interface the screen darkens Pressing any button or rotating any dial awakens the display Dials and buttons You use the dials and buttons To navigate through the...

Страница 8: ...4 Quiet Activation Schedule Level 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 4 Space heating cooling Operation mode Operation mode schedule Room comfort setpoin...

Страница 9: ...ive Powerful operation mode active c Emergency Heat pump failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available vi...

Страница 10: ...in zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temp...

Страница 11: ...e home screen will be greyed out Room temperature control 1 6 bar 55 21 35 45 a 1 6 bar 55 21 35 45 b a Room temperature control ON b Room temperature control OFF Space heating cooling operation 1 6 b...

Страница 12: ...pace You have to tell the system which operation mode to use To tell the system which space operation to use you can You can Location Check which space operation mode is currently used Home screen Set...

Страница 13: ...the DHW tank mode is reheat the risk for capacity shortage and comfort problem is significant In case of frequent reheat operation space heating cooling function is regularly interrupted 5 7 2 Schedu...

Страница 14: ...This example shows how to set a room temperature schedule in heating mode for the main zone INFORMATION The procedures to program other schedules are similar To program the schedule overview Example Y...

Страница 15: ...Tue Sun User defined 1 C 4 Select Paste Delete Edit Copy Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C 5 Repeat this action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined...

Страница 16: ...g Additional zone Cooling Tank only available to installers INFORMATION To operate weather dependent correctly configure the setpoint of the main zone additional zone or tank See 5 9 4 Using weather d...

Страница 17: ...to setpoint mode Set the setpoint mode to 3 4 Additional zone Setpoint mode WD heating fixed cooling OR Weather dependent Additional zone Cooling 3 4 Additional zone Setpoint mode Weather dependent T...

Страница 18: ...sary Example In the morning and evening 7 Maintenance and service 7 1 Overview Maintenance and service The installer has to perform a yearly maintenance You can find the contact helpdesk number via th...

Страница 19: ...consumes extra energy See 5 7 4 Using DHW powerful operation 414 If the problems recurs daily do one of the following Increase the DHW tank temperature preset value See the user reference guide Adjust...

Страница 20: ...smantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recov...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...4P620243 1 2020 06 Copyright 2020 Daikin 4P620243 1 0000000F Verantwortung f r Energie und Umwelt...

Отзывы: