Installation and operation manual
5
FWEC3
Advanced plus electronic controller
FC66002765
036
■
System pipes:
4
■
Valve:
2-3 WAYS
■
Electrical heater:
NO
■
Speeds:
4
■
Summer/winter switching logic:
AIR
037
■
System pipes:
4
■
Valve:
NO
■
Electrical heater:
YES
■
Speeds:
3
■
Summer/winter switching logic:
LOCAL
038
■
System pipes:
4
■
Valve:
NO
■
Electrical heater:
YES
■
Speeds:
4
■
Summer/winter switching logic:
LOCAL
CONFIGURATION OF DIGITAL OUTPUTS
(PARAMETERS
P09,P10,P11,P12
)
P09,P11
= 0
The digital output is not governed by the controller; the contact
is always open.
P09,P11
= 1
The contact status re
fl
ects the current operating mode (summer
or winter) of the unit.
P09,P11
= 2
The contact status indicates the operation mode of the unit:
cooling (summer) or heating (winter).
P09,P11
= 3
The contact status indicates that the unit is in cooling
mode.
P09,P11
= 4
The contact status indicates that the unit is in heating
mode.
P09,P11
= 5
The contact status indicates if the control in ON or OFF
P09,P11
= 6
The contact status indicates if an alarm is triggered (serious
or non-serious, see “Alarms”)
P09,P11
= 7
The contact is used to switch ON/OFF any external device
for dehumidifying the air (cooling mode only). The ON/OFF
logic is based on a reading of the humidity in the room and
the SETPOINT selected with parameter P13. It follows the
diagram shown:
AVAILABLE CONFIGURATIONS (PARAMETER P
00
)
027
■
System pipes:
4
■
Valve:
NO
■
Electrical heater:
NO
■
Speeds:
3
■
Summer/winter switching logic:
AIR
028
■
System pipes:
4
■
Valve:
NO
■
Electrical heater:
NO
■
Speeds:
4
■
Summer/winter switching logic:
LOCAL
029
■
System pipes:
4
■
Valve:
NO
■
Electrical heater:
NO
■
Speeds:
4
■
Summer/winter switching logic:
REMOTE
030
■
System pipes:
4
■
Valve:
NO
■
Electrical heater:
NO
■
Speeds:
4
■
Summer/winter switching logic:
AIR
031
■
System pipes:
4
■
Valve:
2-3 WAYS
■
Electrical heater:
NO
■
Speeds:
3
■
Summer/winter switching logic:
LOCAL
032
■
System pipes:
4
■
Valve:
2-3 WAYS
■
Electrical heater:
NO
■
Speeds:
3
■
Summer/winter switching logic:
REMOTE
033
■
System pipes:
4
■
Valve:
2-3 WAYS
■
Electrical heater:
NO
■
Speeds:
3
■
Summer/winter switching logic:
AIR
034
■
System pipes:
4
■
Valve:
2-3 WAYS
■
Electrical heater:
NO
■
Speeds:
4
■
Summer/winter switching logic:
LOCAL
035
■
System pipes:
4
■
Valve:
2-3 WAYS
■
Electrical heater:
NO
■
Speeds:
4
■
Summer/winter switching logic:
REMOTE
Air humidity
Содержание Advanced plus
Страница 2: ...1 2 5 3 4 ...
Страница 3: ...10 8 11 9 6 7 ...
Страница 4: ...NOTES ...
Страница 21: ......
Страница 39: ......
Страница 57: ......
Страница 75: ......
Страница 93: ......
Страница 111: ......
Страница 129: ......
Страница 147: ......
Страница 165: ......
Страница 183: ......
Страница 185: ...NOTES FC66002554L 1 ...
Страница 186: ......
Страница 187: ...FC66002678 4 UT6600887L 5 ...
Страница 188: ...UT6600888L 6 UT6600889L 7 ...
Страница 189: ......
Страница 190: ......
Страница 191: ...U T 6 6 0 0 1 4 1 6 ...
Страница 192: ...Zandvoordestraat 300 B 8400 Oostende Belgium FC66002765 Stampato su carta riciclata Printed on recycled paper ...