Outdoor Unit
SiBE12-908
219
Removal Procedure
3
Lift the humidifying
rotor up to remove.
A heat catalyst (black) is
applied on the upper side.
3. Removal of the
humidifying rotor motor
1
Disconnect the
connector for the
humidifying rotor
motor.
2
Remove the 2 screws
of the humidifying rotor
motor.
Step
Procedure
Points
(R9900)
Humidifying rotor
(R9901)
(R9902)
Humidifying rotor
motor
Rotor driving
part