SiBE12-908
Indoor Unit
Removal Procedure
194
1.5
Removal of Electrical Box
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
The figure shows the
connections of wire
harnesses.
Preparation
Remove the front grille
according to the “Removal
of Front Grille”.
2
Remove the screw of
the electric wire
retaining plate to
remove the plate.
3
Remove the screws of
the terminal board and
disconnect the
connecting wires.
4
Disconnect the
connector of the fan
motor [S1].
(R10305)
(R10306)
(R10307)
Terminal
board
(R10308)