6.10.2.17 F17: Switchover of memory condition interlocking function (when connected
with the filler control device)
When connected with the filler control device (HC-71D), welding condition memory function of the
welding power source and the wire feed condition memory function of the filler control device can be
interlocked, shearing the memory condition number.
For example, when loading the condition number 2, not only No.2 condition in the welding condition
memory but No.2 condition in the feed conditions memory of the filler control device memory are
loaded.
• [ON]: This function is enabled.
• [OFF]: This function is disabled.
6.10.2.18 F19: Switching alarm setting
When alarm occurs, the output of welding power source can be stopped.
Yet for some alarm codes, it is possible to continue welding even if the alarm level is detected, which may
sometimes cause the alarm display to be ignored. Using the alarm setting switch function ensures to stop
the output from the welding power source.
• [ON]: any alarm detection stops the output of welding power source.
• [OFF]: alarm detection does not stop the output of welding power source.
Means to reset alarms is the same as those for errors, including restoration of the power. ( 9.1
-
Action
in Case of Error)
6.10.2.19 F20: Low input voltage detection level
Set the low input voltage detection level on the primary side. When the input voltage is lower than the
set value, an error code is displayed.
Set the value in the range of 260 to 380 V.
T I P S
• The factory default setting is 320 V. However, the specification of input voltage as welding
power source is the range of 414 to 506 V. If input voltage is lower than this range, it may
affect welding performance.
6.10.2.20 F21: Maximum cooling fan operation
The cooling fan can be rotated at the maximum rotation speed at all time.
• [ON]: The cooling fan rotates at the maximum rotation speed at all time. Even when it is set to [ON],
ensure not to exceed the specified duty cycle. ( 2.1.3
-
Rated duty cycle)
• [OFF]: The cooling fan rotates in a control mode (power-saving operation) due to the temperature
detection inside the welding power source.
This mode is effective in saving power consumption and preventing suction of extra powder dusts.
6.10.2.21 F22: Operation sound switching
Set the operation sound not to be emitted.
• [ON]: Pressing any key on the operation panel enables to sound the operation sound.
• [OFF]: Pressing any key on the operation panel does not enable to sound any operation sound.
Содержание Welbee WB-A350P
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Страница 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Страница 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Страница 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...