7.3 Data Backup (Utilization of data)
This section explains about backup of data such as welding conditions and importing of the backup data.
The following contents can be backed up as csv files in USB flash drive and also imported to the welding
power source.
Backup data can be used for the following applications.
• Copying the same setting to another welding power source
• Analyzing output waveform at the time of failure
• Managing the error history
T I P S
• For the USB flash drive, use the version 1.0. 1.1 or 2.0 with backward compatibility.
• The USB flash drive to be used should be formatted as FAT32.
• Compatibility of the following USB flash drives has been confirmed.
Model No.: SFU22048E3BF2SA-W-D0-111-STD (swissbit)
Model No.: SFU22048E1BP2TO-W-D0-111-STD (swissbit)
• There is software allowing you to easily display waveforms and edit welding conditions. You
can download it from our home page.
URL: http://www.daihen.co.jp/products/welder/software/en.html
7.3.1
Setting of welding conditions/internal functions
The following contents can be stored in the "DAIHEN_OTC_WELDING_PRAMETER.CSV" file.
• All the welding condition data recorded in memory
• The internal function values at the time of data backup
The current welding conditions set with the operation panel will not be saved. (If necessary, record them
in memory beforehand.)
The welding condition data recorded in the memory will be output in the way that the JOB Nos.
(registration Nos.) are displayed in a vertical line and the parameter values in a horizontally line.
No.
Data
Backup
Import
1
Welding Condition
Enabled
Enabled
2
Internal function setting
Enabled
Enabled
3
Simplified data log
Enabled
Disabled
4
Failure log
Enabled
Disabled
5
Welding Result Control Function
Enabled
Disabled
• The backup data (electronic information) may be altered or lost when affected by static
electricity, impact or repair work. . Important information should also be stored as
printed document.
Please note that OTC will not be liable for any alteration or loss of electronic
information.
Содержание Welbee WB-A350P
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Страница 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Страница 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Страница 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...