6-47
Chapter 6
W
elding Condition
O
PERATION
OF
A
NALOG
R
EMOTE
C
ONTROL
(O
PTIONAL
)
W
ELDING
C
ONDITION
C
HAPTER
6
6.11 Operation of Analog Remote Control (Optional)
This section explains the functions of knobs and buttons arranged for the analog remote controller
(optional) as well as their operation.
Since the setting at the analog remote control is preferred when connected, it is not possible to set this
condition on the operation panel of welding power source. (The initial current and crater current can be
set on the operation panel.)
T I P S
• In connecting (or removing) the analog remote control to (or from) the welding power source,
turn OFF the power switch of the welding power source.
• The analog remote control is automatically recognized after being connected to the analog
remote control and turning ON the power switch.
No.
Name
Function
1
Welding current adjustment
knob
Set the welding current. The set value is displayed on the left digital meter at the
welding power source side.
2
Pulse current adjustment knob
Sets the pulse current. The set value is displayed on the left digital meter when the
pulse current is selected with the PARAMETER SELECT key.
3
Scale plate (*1)
The following three scale plates are available.
•
500/400/300/200/100
Change the scale plate according to the selected scale of analog remote control
(
6.10.2.9
-
F9: Analog remote control scale).
4
Fixing screw
To replace the scale plate, turn the screw counter clockwise, and remove them.
*1: When adjusting in a low current range in such a case when welding a sheet metal, fine adjustment can be carried
out by using the attached scale plate of 100 A full scale. To use the 100 A scale plate, set the internal function
F9 to "100". (
6.10.2.9
-
F9: Analog remote control scale)
1
2
4
3
Содержание Welbee WB-A350P
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12 ...
Страница 52: ...CONNECTION OF EXTERNAL EQUIPMENT CONNECTION CHAPTER 4 4 18 ...
Страница 108: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 48 ...
Страница 138: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram ...
Страница 139: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 ...