C
ONNECTING
THE
W
ELDING
P
OWER
S
OURCE
C
ONNECTION
C
HAPTER
4
4-6
4.2.4
Connection at TIG welding
1.
Remove the output terminal cover.
2.
Connect the power cable for torch side to the output terminal (base metal side).
●
At the welding power source side, remove the fixing screws of the output terminals. Fix firmly the
round terminals of the power cable for base metal side with the fixing screws.
3.
Connect the power cable for base metal side to the output terminal (torch side) and base metal.
●
Connect the connectors as same as above.
4.
Restore the output terminal cover.
• In using the welding power source for TIG welding, prepare a welding torch by the
customer.
• Contrary to the normal connection, the TIG welding requires connection of the welding
torch to the output terminal (base metal side). Also, connect the power cable for base
metal side to the output terminal (torch side).
• After five seconds have passed, the safety voltage (approx.15 V) is automatically
provided.
Ground a base metal if
required by local law.
Power cable for base metal side
Base metal
Power cable for
torch side
Welding power source
Output terminal
(Base metal side)
Output terminal
(Torch side)
Output terminal cover
Содержание WB-M500
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18...
Страница 106: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 44...
Страница 134: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 144: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 10...