4-3
Chapter 4
Connection
C
ONNECTING
THE
W
ELDING
P
OWER
S
OURCE
C
ONNECTION
C
HAPTER
4
4.2.1
Connection of cable at output side
This section explains the procedure for connecting of cable at output side.
1.
Remove the output terminal cover.
2.
Connect the power cable for base metal side to the output terminal (base metal side) and base
metal.
●
At the welding power source side, remove the fixing screws of the output terminals. Fix firmly the
round terminals of the power cable for base metal side with the fixing screws.
3.
Connect the power cable for torch side to the output terminal (torch side).
●
Connect the connectors as same as above.
4.
Restore the output terminal cover.
Connection for cable at output side is complete. Procedure is followed by 4.2.2
-
• Use a grounding cable for the case, of welding power source and perform grounding.
Otherwise, voltage may increase in the case or base metal which could cause electric
shock.
Ground a base metal if
required by local law.
Base metal
Power cable for
base metal side
Power cable for torch side
Welding power source
Output terminal
(Base metal side)
Output terminal
(Torch side)
Output terminal cover
Содержание WB-M500
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO...
Страница 28: ...PART NAMES PRODUCT SPECIFICATION AND CONFIGURATION CHAPTER 2 2 12...
Страница 52: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 18...
Страница 106: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 44...
Страница 134: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 144: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 10...