I
NSULATION
R
ESISTANCE
M
EASUREMENT
AND
W
ITHSTAND
V
OLTAGE
T
EST
M
AINTENANCE
AND
I
NSPECTION
C
HAPTER
8
8-6
–
For DR1, 2 and 4, short-circuit the AC side and positive (+) output side and the AC side and negative
( - ) output side respectively.
–
Short-circuit between TR1(C1)-(E1), TR2(C2)-(E2), TR4(C2)-(E2), TR5(C1)-(E1), TR5(C2)-(E2).
–
Apply NF.
–
After finishing insulation resistance measurement, return the above to the original state.
• After finishing insulation resistance measurement, it is necessary to remove the
shortcircuit cables and return the welding power source to the original state.
If the power is turned on without returning it to the original state, the welding power
source will burn out.