6-5
Chapter 6
W
elding Condition
L
IST
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
F55
Arc loss detection time
OFF (fixed)
OFF
Used when connecting with OTC automatic
machine.
-
F56
Arc start error
detection time
F57
WCR output ON
delay time
F58
WCR output OFF
delay time
F59
Analog setting switch
F60
No function
OFF (fixed)
OFF
No functions are provided.
-
F61
F62
F63
F64
F65
F66
F67
Setting change of current
value (initial condition, crater
condition)
OFF/ON
OFF
When “CRATER ON” is selected, sets the current
value of the initial condition and crater condition
in the percentage based on the current value of
the welding condition.
OFF: invalid
ON: settable with percentage
-
F68
Setting of current value
(initial condition)
10 to 300
100 (%)
Sets the current value of the initial condition in the
percentage based on the current value of the
welding condition.
-
F69
Setting of current value
(crater condition)
10 to 300
100 (%)
Sets the current value of the crater condition in
the percentage based on the current value of the
welding condition.
-
No.
Function Name
Setting range
Initial value
Explanation