7-16
1.
Turn off the power switch.
2.
Press and hold the F (function) key and GAS CHECK key simultaneously and turn on the power
switch.
3.
Check that "End" is displayed on the left/right digital meters and turn off the power switch.
⇒
The power LED switch lights off. The status returns to normal when the power switch is turned on.
7.5 Checking Software Version
This section explains how to check the software version installed in the welding power source.
The software version is managed as below.
1.
Turn off the power switch.
2.
Press and hold the F (function) key and turn on the power switch.
⇒
The Product No. is displayed on the left and right digital meters.
⇒
The display changes every time the F (function) key is pressed.
(The display order of 5 or later is for manufacturer's management. It is not necessary for the user to
check it.)
3.
After checking, turn off the power switch.
⇒
The power LED switch lights off. The status returns to normal when the power switch is turned on.
●
Hold the two keys pressed down until "End" is
displayed on the left/right digital meters.
⇒
Initialization starts.
Display order
Display Content
Left digital meter
Right digital meter
1
Product No
Product No
2
Main version
"---"
3
Minor version
Minor version
4
"---"
Extended version
5 or later
Version for management
A
V
r
㧑
GAS CHECK
F
ON
+
WARNING
IPM.
sec.
JOB No.
Hz
P## ### Ver. ### ### ### ###
Product
Main version
Extended version
Minor version
Содержание OTC Welbee M350L
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 138: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6 ...
Страница 150: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 12 ...