O
PERATION
OF
A
NALOG
R
EMOTE
C
ONTROL
(O
PTIONAL
)
W
ELDING
C
ONDITION
C
HAPTER
6
6-46
6.8 Operation of Analog Remote Control (Optional)
This section explains the functions of knobs and buttons arranged for the analog remote controller
(optional) as well as their operation.
Since the setting at the analog remote control is preferred when connected, it is not possible to set this
condition on the operation panel of welding power source. (The initial condition and crater condition can
be set on the operation panel.)
T I P S
• In connecting (or removing) the analog remote control to (or from) the welding power source,
turn OFF the power switch of the welding power source.
• The analog remote control is automatically recognized after being connected to the analog
remote control and turning ON the power switch.
No.
Name
Function
1
Welding current adjustment
knob
Set the welding current. The set value is displayed on the left digital meter at the
welding power source side.
2
Welding voltage adjustment
knob
Set the welding voltage. The set value is displayed on the right digital meter at the
welding power source side.
• < SYNERGIC adjustment >
Optimum welding voltage according to the welding current is automatically set,
and fine adjustment is available for the set welding voltage.
Align the welding voltage adjustment knob to the center ("
●
" mark), and adjust
the voltage with the position as the standard.
• < INDIVIDUAL adjustment >
The welding voltage can be individually adjusted without being influenced by the
welding current.
3
Inching button
Feeds the wire. (
-
During when the button is pressed, the wire feeding is carried out.
Wire feed speed can be adjusted by the welding current adjustment knob while
pressing the inching button.
4
Scale plate (*1)
Replace the scale plate for analog remote control (
-
control scale) when using the optional analog remote control. Note that the scale of
analog remote control as well as the scale plate to be used depends on the rated
output current of the welding power source. (Above diagram shows an example with
350 A)
• 350A: 350/200
• 500A: 500/350/200
5
Fixing screw
To replace the scale plate, turn the screw counter clockwise, and remove them.
*1: For adjustment of low current region when using a thin wire, etc., using the accessory scale plate with full scale
of 200A allows fine adjustment. To use this scale plates, set the internal function F9 function. (
SINERG. FINE ADJ.
LOW
HIGH
INCHING
JOB No.
Welding current(A)
For CO2/MAG/MIG
1
2
3
5
4
Содержание OTC Welbee M350L
Страница 2: ......
Страница 8: ...TABLE OF CONTENTS vi MEMO ...
Страница 138: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6 ...
Страница 150: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 12 ...