S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
6-32
• [1] to [30]: enables the function. Turning the welding current adjustment knob on the analog remote
control enables to fine adjust the current, and turning the voltage knob enables to fine adjust the voltage.
–
Setting range : 1 to 30 %
–
Turning both of the current and voltage knobs to the center of scales sets the welding conditions to
those stored on the welding condition memory. Adjust the current/voltage with the standard of the
center of scales. To increase the welding current or voltage, turn the knob counterclockwise and to
reduce the welding current or voltage, turn the knob clockwise.
• In the following cases, this function cannot be used:
–
Welding conditions are not registered to the memory;
–
Analog remote control (optional) is not connected to the welding power source;
–
Internal function F44 (Reading welding condition with remote control) is set to "ON" (enabled);
–
Internal function F45 (Special crater sequence) is set to "ON" (enabled);
–
Internal function F48 (Adjusting current with torch switch) is set to "ON" (enabled); or
–
Internal function F51 (Special crater repeat) is set to "ON" (enabled); or
–
Either of the internal functions F29 to F32 (External input terminal setting) is set to either "4" (Start) or
"5" (Loading welding condition).
–
Internal function F4 (Auto/Semi-auto mode) is set to a value other than "0" (Semi-auto mode).
6.7.2.12 F12: Operation time of water-cooled pump
Sets the operation time of water-cooled pump after welding ends.
When the water-cooled welding torch is used, the water-cooled pump operates to cool the welding torch
as the welding ends. The operation time of water-cooled pump at this time can be set:
• Setting range of water-cooled pump operation time: 20 to 60 min.
• “ON”: Water-cooled pump is always ON
6.7.2.13 F14/F15: Start control (time/current) adjustment
Set the time and current for start control to be performed at the time of welding start.
Depending on the welding conditions and set current value, the appropriate time and current for start
control are determined; if proper burning of the wire does not occur at the time of start, adjust the time
and current for start control.
For more intense burning, increase the time and current.
For less intense burning, reduce the time and current.
• Set the time from -50 to 50 % through F14 (Start control time adjustment).
• Set the current in the range from -100 to 100 A through F15 (Start control current adjustment).
Place these knobs in the center positions.
Содержание OTC Welbee Inverter W400
Страница 2: ......
Страница 8: ...vi MEMO...
Страница 56: ...WIRING OF VOLTAGE DETECTION CABLE AT BASE METAL SIDE CONNECTION CHAPTER 4 4 22...
Страница 116: ...OPERATION OF ANALOG REMOTE CONTROL OPTIONAL WELDING CONDITION CHAPTER 6 6 50...
Страница 134: ...CHECKING SOFTWARE VERSION ADMINISTRATOR FUNCTIONS CHAPTER 7 7 18...
Страница 146: ...TROUBLESHOOTING TROUBLESHOOTING CHAPTER 9 9 6...
Страница 150: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 10 4 10 2 1 Schematic diagram...
Страница 151: ...10 5 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10...
Страница 158: ...MATERIALS FOR SETTING WELDING CONDITIONS REFERENCE MATERIALS CHAPTER 10 10 12...